摘要 T波电交替(TWA)是指体表心电图中T波形态、振幅、极性、持续时间或者整个ST-T波段逐搏交替变化的心电变异现象。相关方法能很好地检测非稳态的TWA,但是它本身对噪声非常敏感。本文在原相关方法计算相关指数的基础上,通过改进TWA发生的判定条件并采用线性拟合的办法,有很好的抗噪声干扰能力,从而达到了检测非稳态TWA的效果。通过模拟和临床数据试验证实了本方法的有效性。 T-wave alternans(TWA) refers to a phenomenon appearing in the surface electrocardiograph(ECG) as a consistent fluctuation in morphology and amplitude of the T wave on an "every-other-beat" basis.Correlation method(CM) has a certain ability to detect the non-stationary TWA,but it is very sensitive to noise.In this paper we propose a modified correlation method to ensure a stable and accurate detection of non-stationary TWA.Compared to the CM,the method modifies the judge condition and uses the linear fitting to limit the noise to gain the ability of detecting of non-stationary TWA.Our simulation and clinical data assessment study demonstrates the improved performance of the proposed algorithm.
出处 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2013年第4期860-865,共6页 Journal of Biomedical Engineering
基金 国家自然科学基金资助项目(60901027)
关键词 T波电交替 最小二乘法拟合 相关分析法 T-wave alternans(TWA) Least squares method Correlation method(CM)
  • 相关文献

参考文献12

  • 1WALKER M L, ROSENBAUM D S. Repolarization alter- nans: implications for the mechanism and prevention of sudden cardiac death[J].Cardiovasc Res, 2003, 57(3): 599-614.
  • 2COSTANTINI O, DRABEK C, ROSENBAUM D S. Can sudden cardiac death be predicted from the T wave of the ECG? A critical examination of T wave alternans and QT in- terval dispersion[J]. Pacing Clin Electrophysiol, 2000, 23 (9):1407-1416.
  • 3SHIMIZUW, ANTZELEVITCH C. Cellular and ionic basis for T-wave alternans under long-QT conditions[J]. Circula- tion, 1999, 99(11): 1499-1507.
  • 4张石,佘黎煌,徐中强,宋宇宁.心电T波电交替检测算法综述[J].中国生物医学工程学报,2010,29(3):446-453. 被引量:11
  • 5CUESTA-FRAU D, MICO-TORMOS P, ABOY M, et al. Enhanced modified moving average analysis of T-wave alter- nans using a curve matching method: a simulation study[J]. Med Biol Eng Comput, 2009, 47(3): 323-331.
  • 6沈永林,蔡志鸿,孙小苍.心电微伏T波交替检测的一种方法[J].清华大学学报(自然科学版),2004,44(4):462-465. 被引量:5
  • 7BURATTINI L, ZAREBA W, MOSS A J. Correlation meth- od for detection of transient T-wave alternans in digital Holter ECG recordings[J]. Ann Noninvasive Electrocardiol, 1999, 4 (4): 416-424.
  • 8BURATTINI L, BINI S, ROBERTO B. Correlation method versus enhanced modified moving average method for auto- matic detection of T-wave alternans[J]. Comput Meth Pro- grams Biomed, 2010, 98(1): 94-102.
  • 9MCSHARRY P E, CLIFFORD G D, TARASSENKO L, et al. A dynamical model for generating synthetic electrocardio- gram signals[J]. IEEE Trans Biomed Eng, 2003, 50 (3): 289-294.
  • 10KHAUSTOV A, NEMATI S, CLIFFORD G D. An open- source standard T-wave alternans detector for benchmarking [C]//Computers in Cardiology, Bologna: 2008: 509-512.

二级参考文献73

  • 1王友武,王桂英,刘宏,王风菊.动态心电图若干技术伪差分析[J].心电学杂志,1995,14(3):183-185. 被引量:5
  • 2沈永林,郑岚,陈文辉,梁毓厚,杨虎.基于 Windows 平台上的标准12导联 ECG 信号同步采集及分析软件[J].航天医学与医学工程,1997,10(1):44-48. 被引量:2
  • 3安勇,张志菓,张建兴,李川勇.心绞痛患者T波交替的检测与分析[J].北京生物医学工程,2007,26(4):381-385. 被引量:1
  • 4Herlng HE. Experimentelle studlen an Sliugetieren tiber das Elektrocardiogram[J]. Zeitschrift fur experimenteUe PathoIogie and Therapie, 1909, 7 : 363 - 378.
  • 5Kaher HH, Schwartz ML. Electricular altermans [ J]. NY State J Med, 1948, 1: 164.
  • 6Hellerstein HK, Liebow IM. Electrical ahernan in experimental coronary artery occlusion [J]. Am J Physiol, 1950, 160:366 - 374.
  • 7Adam DR, Smith JM, Akselrod S, et al. Fluctuations in T-wave morphology and susceptibility to ventricular fibrillation [ J ]. J Electrocardiol, 1984, 17 ( 3 ) : 209 - 218.
  • 8Rosenbaum DR, Jackson LE, Smith JM, et al. Electrical altemans and vulnerability to ventricular arrhythmias [ J ]. N Engl J Med, 1994, 330(4) : 235 -241.
  • 9Laguna P, Ruiz M, Moody GB, et al. Repolarization alternans detection using the KL transform and the beatquency spectrum [A]. In: Computers in Cardiology [C ]. New York: IEEE, 1996. 673-676.
  • 10Nearing BD, Huang AH, Verrier RL. Dynamic tracking of cardiac vulnerability by complex demodulation of the T wave [J]. Science, 1991, 252(5004): 437 -440.

共引文献108

同被引文献13

  • 1赵捷,华玫.基于T波最大值的T波电交替分析法[J].生物医学工程学杂志,2005,22(5):951-955. 被引量:10
  • 2FURLANELLO F, GALANTI G, MANETTI P. Micro- volt T-wave alternans as predictor of electrophysiological testing results in professional competitive athletes [ J ]. Ann Noninvasive Electrocardiol, 2004, 9 ( 3 ) : 201 - 206.
  • 3VERRIER R L, IKEDA T. Ambulatory ECG-based T- wave alternans monitoring for risk assessment and guid- ing medical therapy: Mechanisms and clinical applica- tions [ J ]. Progress in Cardiovascular Diseases, 2013, 56(2) :172 - 183.
  • 4ARMOUNDAS A A, MELA T, MERCHANT F M. On the estimation of T-wave ahernans using the spectral fast fourier transform method [ J]. Heart Rhythm, 2012, 9 (3) : 449 -456.
  • 5BUR ATrlNI L, BINI S, BURATrlNI R. Correlation method versus enhanced modified moving average method for automatic detection of T-wave alternans [J], Computer Methods and Programs in Biomedicine, 2010, 98( 1 ) : 94- 102.
  • 6STRUMILLO P, RUTA J. Poincar6 mapping for detecting abnormal dynamics of cardiac repolarization [ J ]. IEEE Eng Med Biol Mag, 2002, 21 (1) : 62 -65.
  • 7CUESTA F,MICO T P, ABOY M. Enhanced modified moving average analysis of T- wave alternans using a curve matching method : a simulation study [ J ]. Medi- cal & Biological Engineering & Computing, 2009 , 47 (3) : 323 - 331.
  • 8MARTiNEZ J P, OLMOS S. Methodological principles of T wave ahernans analysis:a unified framework [ J ]. IEEE Transactions on Bio-medical Engineering,2005,52 (4) :599-613.
  • 9NARAYAN S M, BOTI'ERON G W, SMITH J M. T- wave alternans spectral magnitude is sensitive to ECG beat alignment strategy[ J]. IEEE Trans on Computer in Cardiology, 1997, 24 (3) : 593 - 596.
  • 10魏珑,赵捷,徐舫舟,赵艳娜.基于相关分析方法的非稳态心电T波交替检测研究[J].现代生物医学进展,2009,9(16):3131-3134. 被引量:6

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部