摘要 目的:设计一种便携式高精度的磁感应相位检测装置。方法:设计一种基于梯度线圈主磁场抵消技术以及新型鉴相芯片SYPD-1的便携式医用磁感应测量装置。整个系统包括梯度线圈结构、差动放大器、鉴相器、单片机处理电路和显示电路。SYPD-1是新上市的无源鉴相芯片,鉴相带宽1~100 MHz,灵敏度8 mV/(°),相位差分辨率不超过0.03°,是当前分辨率最高的鉴相芯片,使用方便。结果 :该装置可以分辨出电导率为0.5、1.3、7.8 S/m的3种同体积NaCl溶液,且具有较好的线性度。结论:该磁感应测量装置实现了高精度和便携式的要求,具有一定的实用价值和很大的改进空间。 Objective To design a portable and high precision magnetic induction phase measuring device. Methods The main magnetic field cancelling technique by gradient coils and SYPD-1 phase detector were used to develop the device, which was composed of gradient coils, differential amplifier, phase detector, MCU processing circuit and display circuit. SYPD-1 phase detector was passive and had a 1 to 100-MHz bandwidth, an 8 mV/(°) sensitivity, a phase difference resolution not more than 0.03°. Remtlts The experiments showed that the device could distinguish three kinds of NaCI solutions with the same volume and the conductivities of 0.5, 1.3 and 7.8 S/m respectively. Collclusioll The magnetic induction measuring device, being high-precision and portable, is worth popularizing practically, while has some defects to conquer.
出处 《医疗卫生装备》 CAS 2013年第8期7-9,23,共4页 Chinese Medical Equipment Journal
基金 国家科技支撑计划(2009BAI87B00) 创伤 烧伤与复合伤国家重点实验室课题(SKLZZ200903)
关键词 磁感应 相位差 电导率 梯度线圈 SYPD-1 magnetic induction phase difference conductivity gradient coil SYPD-1
  • 相关文献

参考文献10

  • 1秦明新,李世俊,董秀珍,等.非接触磁感应脑电导率断层成像系统实验系统研究[C]//中国科协2003年学术年会文集.北京:中国科学技术出版社.2003:314.
  • 2金贵,秦明新,王超,郭万有,徐林,宁旭,许佳.基于PSSMI方法的脑水肿模拟检测实验研究[J].中国医学物理学杂志,2011,28(4):2771-2775. 被引量:4
  • 3Korjenevsky A,Cherepenin V,Sapetsky S. Magnetic induction to-mography : experimental realisation[J]. Physiol Meas,2000,21 (1) 89-94.
  • 4Griffith H. Magnetic induction tomography[J]. Meas Sci Technol 2001,12:1 126-1 131.
  • 5Igney C H,Watson S,Williams R J,et al. Design and performance of a planar-array MIT system with normal sensor alignment[J]. Physiol Meas, 2005,26 ($2) : 63-78.
  • 6Watson S, Morris A, Williams R J ,et a/. A primary field compensa- tion scheme for planar array magnetic induction tomography [J]. Physiol Meas, 2004,25 : 271-279.
  • 7金贵,王超,郭万友,等.磁感应法测量脑水肿中鉴相器的设计[J].医疗卫生装备,2011,32(10):180-182.
  • 8胡晓彦,秦明新,焦明克,梁文文,张华.磁感应成像系统中相位检测方法研究[J].医疗卫生装备,2007,28(4):11-13. 被引量:8
  • 9敖振浪,李源鸿,谭鉴荣.十六位模数转换器AD7705及其应用[J].成都信息工程学院学报,2003,18(3):281-286. 被引量:28
  • 10刘红玲.16位∑-△A/D转换器AD7705及其应用[J].单片机与嵌入式系统应用,2002,2(1):47-58. 被引量:4

二级参考文献15

共引文献42

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部