摘要
以宁波市罗蒙室内游乐场为例,对适用于大空间场所的水消防自动灭火系统进行对比分析,选用了自动消防炮灭火系统。详细介绍了自动消防炮稳高压给水系统的管网水头损失、供水压力及稳压设施技术参数等的计算过程。
Taking Ningbo Romon indoor amusement park for example, the automatic fire monitoring extin- guishing system was selected after comparatively analyzing water fire extinguishing system for large-space site. The calculation process of head loss of the automatic fire monitor water supply system of stable-high pressure, the fire water supply pressure and the technical parameters of stable pressure facilities were introduced in detail.
出处
《工业用水与废水》
CAS
2013年第4期81-85,共5页
Industrial Water & Wastewater
关键词
大空间场所
自动消防炮
稳高压给水系统
管网平差
稳压设施
large-space site
automatic fire monitor
water supply system of stable-high pressure
hydraulic adjustment of pipe network
stable pressure facilities