摘要
对涂装厂工业以太网系统出现的传输故障进行分析,排查故障原因,更换损坏端口,彻底解决系统传输故障,恢复涂装厂设备的正常监控。
Analysis of transmission failure of industrial Ethernet system coating factory,reasons for troubleshooting,replace the damaged port,completely solve the transmission system fault,the normal monitoring recovery Coating Factory equipment.
出处
《中国科技信息》
2013年第16期87-87,共1页
China Science and Technology Information
关键词
以太网
IP地址
交换机
PMC系统
ethernet network
IP address
exchange board
PMC system