摘要
在配制氧化亚氮与氧气混合气过程中,充装完氧化亚氮之后再充装氧气时,气瓶上下的温差非常大。阐述了通过实验解决气瓶上下温度差的问题。
During preparing the mixture gases of nitrous oxide and oxygen, the temperature of the cylinder varies greatly be- tween top and bottom when filling oxygen into the cylinder after filled nitrous oxide. The article elaborated how to solve the temperature difference of the cylinder by the test.
出处
《低温与特气》
CAS
2013年第4期28-31,共4页
Low Temperature and Specialty Gases
关键词
混合气
均匀性
稳定性
氧化亚氮
氧气
mixture gases
homogenization
stabilization
nitrous oxide
oxygen