对高压甲铵预热器爆管原因进行了分析,通过对高压甲铵预热器管壁涡流检测堵管和高压氨预热器的投用,彻底解决了高压甲铵预热器爆管给整个水溶液全循环法尿素胺装置带来危害的问题.
Reasons for squib in high-pressure methylamme preheater are analyzed. lhe harm is completely solvea which is caused by tube explosion in high-pressure methylamine preheater and brings dangerous to the entire urea amine device of total aqueous solution circulation, by using the wall vortex detection tube plugging in high-pressure methylamine preheater blocked tubes and high-pressure ammonia preheater.
出处
《新乡学院学报》
2013年第3期189-191,194,共4页
Journal of Xinxiang University
关键词
高压甲铵预热器
爆管
温差应力
涡流检测
high-pressure methylamine preheater
squib
thermal stress