分段优化方法在鼻咽癌调强计划临床应用的可行性研究

The feasibility of clinical application of piecewise optimization methods used in nasopharyngeal carcinoma intensity modulated plan design
下载PDF
导出
摘要 目的:介绍一种分段优化方法在鼻咽癌调强计划设计中的应用。方法:分段优化方法是指将调强计划分两段计划优化和执行,第一段计划优化靶区包括肿瘤区、阳性淋巴结区、高危区和预防照射区,执行同期小野加量治疗,第二段计划只针对肿瘤区进行缩野推量。该方法的应用过程和效果用1例鼻咽癌病例做演示。结果:对于鼻咽癌,分段优化方法的调强计划设计相对传统同期小野加量调强计划设计可以提高高危区和预防区单次剂量,靶区剂量分布更加均匀,减少重要器官受量,同时减少计划投射跳数。结论:分段优化方法可以在鼻咽癌调强计划设计中应用。 Objective:To introduce a piecewise optimization methods used in nasopharyngeal carcinoma intensity modula- ted plan design. Methdos : Piecewise optimization are the methods to carry out the intensity modulated plan in two pro- grams, the first program optimization include the tumor area, positive lymph nodes area, high-risk area and prophylactic area, the second program only irradiates the tumor area. The application of piecewise optimization methods was demonstra- ted in a patient with nasopharyngeal carcinoma. Results:For nasopharyngeal carcinoma, pieeewise optimization intensity modulated and improved the single dose of the prophylactic and high-risk irradiation area, made the target dose distribu- tion more uniformed, reduced the dose of organs at risk and reduced the treatment delivery time. Conclusions : The piece- wise optimization methods can be used in nasopharyngeal carcinoma intensity modulated plan design.
出处 《赣南医学院学报》 2013年第4期516-519,共4页 JOURNAL OF GANNAN MEDICAL UNIVERSITY
基金 2012年赣州市科技局课题
关键词 调强计划 分段优化 单次剂量 计划品质 Intensity modulated plan Piecewise optimization Single dose Plan quality
  • 相关文献

参考文献8

  • 1Saw CB,Zhen W, Ayyangar KM, et al. Different doses to separate targets using intensity-modulated radiation thera- py [ J ]. Electormedica1,2001,69 (2) : 131 - 135.
  • 2Lee AWM, Chan DKK, Fowler JF, et al. Effect of time, dose and fraetionation on local control of nasopharyngeal carcinoma [ J ]. Radiother Oncol, 1995,36 : 24 - 31.
  • 3谭榜宪,张有望,胡超苏,吴永如,冯炎.鼻咽癌常规分割放疗中的时间剂量效应关系[J].中华放射肿瘤学杂志,1998,7(1):41-45. 被引量:36
  • 4崔念基.分割放射治疗的生物学基础及其临床应用[C].见:崔念基.实用临床放射肿瘤学[M].广州:中山大学出版社,2005:164.
  • 5韩露,林少俊,邹长炎,吴章贵,吴爱敏,陈奇松,潘建基.调强放疗延长单次分割照射时间对鼻咽癌细胞系放射生物学效应的影响[J].福建医药杂志,2009,31(6):78-80. 被引量:4
  • 6Michael K. M. Kam, Peter M. L Teo, Ricky M. C. Chau, et al. Treatment of nasopharyngeal carcinoma with intensity- modulated radiotherapy : The Hong Kong experience[ J ]. International Journal of Radiation Oncology Biology Phys- ics ,2004,60(5 ) :1440 - 1450.
  • 7Nancy Lee, Ping Xia, Jeanne M Quivey, et al. Intensity- modulated radiotherapy in the treatment of nasopharynge- al carcinoma: an update of the UCSF experience[ J]. In- ternational Journal of Radiation Oncology Biology Phys- ics ,2002,53 ( 1 ) : 12 - 22.
  • 8王运来,戴相昆,马林,冯林春,曲宝林.子野直接优化方法提高鼻咽癌调强放疗下颈部靶区的分次剂量[J].中华放射医学与防护杂志,2009,29(3):313-315. 被引量:2

二级参考文献28

  • 1钱立庭,杨伟志,刘新帆.模拟IMRT模式的生物效应研究初探[J].中华放射肿瘤学杂志,2005,14(5):431-433. 被引量:30
  • 2袁智勇,高黎,徐国镇,易俊林,黄晓东,罗京伟,李素艳,戴建荣.初治鼻咽癌调强放疗的初步结果[J].中华放射肿瘤学杂志,2006,15(4):237-243. 被引量:84
  • 3Wolden SL, Chen WC, Pfister DG, et al. Intensity-modulated radiotherapy (IMRT) for nasopharynx cancer: update of the Memorial Sloan-Kettering experience. Int J Radiat Oncol Biol Phys, 2006,64(1):57-62.
  • 4Oelfke U, Bortfeld T. Inverse planning for photon and electron beams. Med Dosm, 2001,26(2) : 113-124.
  • 5Hunt MA, Zelefsky MJ, Wolden S, et al. Treatment planning and delivery of intensity-modulated radiotherapy for primary nasopharynx cancer. Int J Radiat Oncol Biol Phys, 2001, 49(3) : 623-632.
  • 6Saw CB, Zhen W, Ayyangar KM, et al. Different doses to separate targets using intensity-modulated radiation therapy. Electromedica, 2001,69(2) : 131-135.
  • 7Stell AM, Li JG, Zeidan OA, et al. An extensive log file analysis of step and shoot intensity modulated radiateon therapy segment delivery errors [J]. Med Phys, 2004, 31 (6): 1593-1602.
  • 8Chang SX, Cullip TJ, Deschesne KM. Intensity modulation delivery technique: step and shoot MLC auto-sequence versus the use of a modulator [J]. Med Phys, 2000, 27 (5): 948-959.
  • 9Verhey LJ. Physical considerations in the sue of intensity modulated radiotherapy to produce lhree-dimensional conformal dose distributions [J]. J Jpn Soc Ther Radiol Oncol, 2000, 12 (1) 191 203.
  • 10Fowler JF, Welsh JS, Howard SP. Loss of biological effect in prolonged fraction delivery [J]. Int J Radiation Oncology Biol Phys, 2004, 59 (1): 242-249.

共引文献37

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部