摘要 利用化学成分分析、力学性能检验以及金相组织分析等方法,对SPA-H钢板冷弯开裂现象进行了分析。结果表明,SPA-H钢板表面带状组织级别达到4级,表面分布大量球状氧化铝夹杂是造成冷弯开裂的主要原因。 The reasons leading to cold bend cracks on the surface of a SPA-H steel plate are analyzed by such methods as chemical composition analysis, mechanical properties test and metal- lographic structure analysis. The analytical results show that the lamellar structure on the surface of the SPA-H steel plate is Level 4 which means that massive spherical alumina inclusions dis- tributed on the surface of the SPA-H steel plate are the principal reason leading to cold bend cracks.
出处 《鞍钢技术》 CAS 2013年第4期51-54,共4页 Angang Technology
关键词 SPA-H钢 缺陷 冷弯开裂 带状组织 氧化铝 SPA-H steel defect cold bend crack lamellar structure aluminum oxide