期刊文献+

铸造Twin-Flex卡环修复KennedyⅡ类牙列缺损的临床应用 被引量:4

Clinical application of casted Twin-Flex clasp for restoration of Kennedy Ⅱ dentition defect
下载PDF
导出
摘要 目的研究整体铸造法制作的Twin-Flex卡环在KennedyⅡ类牙列缺损修复中的使用效果。方法15例KenendyⅡ类牙列缺损患者,应用铸造支架材料整体铸造Twin-Flex卡环进行活动义齿修复,评价义齿的美学效果,固位、支持及稳定性。结果 15例患者,采用整体铸造法制作的Twin-Flex卡环,KennedyⅡ类牙列缺损的末端基牙避免了唇颊侧卡环的暴露,美学效果良好,义齿固位、支持及稳定效果良好。结论整体铸造法制作的Twin-Flex卡环应用于KennedyⅡ类牙列缺损修复,符合游离端设计的基牙及牙槽骨生物力学要求,可取得较好的美学效果及临床应用效果。 Objective Tu evaluate the effect of casted Twin-Flex clasp used on the terminal abutment of unilateral free ending dentition defect. Methods Fifteen cases were selected,and the casted Twin-Flex clasp was used on the ter- minal abutment of unilateral free ending dentition defect. Results The casted Twin-Flex clasp used on the terminal abut- ment of unilateral free ending dentition defect conformed to the biomechanics rule of the terminal abutment and the eden- tulous ridge. Better retention and stabilization of the removable partial denture were achieved. Conclusion The use of casted Twin-Flex clasp on terminal abutment could provid a satisfactory result for unilateral free ending dentition defect.
出处 《广东牙病防治》 2013年第8期432-434,共3页 Journal of Dental Prevention and Treatment
关键词 牙列缺损 可摘局部义齿 Twin—Flex卡环 Dentition defect Removable partial denture Twin-tlex clasp
  • 相关文献

参考文献9

  • 1Burns DR, Ward JE. A review of attachmants for removable partial denture design : part I. Chtssification and selection[ J ].Int J Prosth- odont, 1990,3( 1 ) :98-102.
  • 2Firtell DN, Jacobson TE. Remowlble partial dentures with rotational paths of insertion : problem analysis [ J ]. J Prosthet Dent, 1983,50( 1 ) :8-15.
  • 3Krol A J, Finzen FC. Rotational path removable partial dentures: part- 2. Replacement of anterior teeth [ J ]. lnt Prosthodant, 1988,1 (2) : 135-142.
  • 4Pardo-Mindan S, Ruiz-ViLlamtiego JC. A flexible lingual clasp as an esthetic alternative: a clinical report[ J]. J Prosthet Dent, 1993,69 (3) :245-246.
  • 5Belles DM. The Twin-Flex elasp: an esthetic alternative[ J ]. J Pros- ther Dent, 1997,77 (4) :450-452.
  • 6Mansueto MA, Phoenix RD. The Twin-Flex removable partial den- ture: design, fabrication, and clinical usage[ J ]. J Prosthod, 1998, 7(4) :268-272.
  • 7Santana-Penin U, Mora MJ. An esthetically attractive twin-flex clasp far removable partial dentures [ J ]. J Prnsthet Dent, 1998,80 ( 3 ) : 367-370.
  • 8张倩,程祥荣,S.M.Kollab.Twin-Flex美观卡环在可摘局部义齿中的临床应用[J].中华医学美学美容杂志,2005,11(2):80-84. 被引量:1
  • 9冯海兰.口腔修复学[M].北京:北京大学医学出版社,2007:168-180.

二级参考文献12

  • 1Burns DR, Ward JE. A review of attachments for removable partial denture design: part Ⅰ.classification and selection. Int J Prosthodont, 1990,3:98-102.
  • 2Hansen CA,Iverson GW. An esthetic removable partial denture retainer for the maxillary canine. J Prosthet Dent,1986,56:199-203.
  • 3Firtell DN, Jacobson TE. Removable partial dentures with rotational path of insertion: problem analysis. J Prosthet Dent,1983,50:8-15.
  • 4Ticonium company.Technology:Ticonium's twin-flex clasp. Strack J ed. Contacts,1977,2:3-4.
  • 5Belles DM. The Twin-Flex clasp: an esthetic alternative. J Prosthet Dent,1997,77:450-452.
  • 6Santana-Penin U, Mora MJ. An esthetically attractive twinflex clasp for removable partial dentures. J Prosthet Dent,1998,80:367-370.
  • 7Silness J, Loe H. Periodontal disease in pregnancy: Ⅱ. Correlation between oral hygiene and periodontal condition. Acta Odontol Scand,1964,22:121-35.
  • 8Loe H, Silness J. Periodontal disease in pregnancy: Ⅰ. Prevalence and severity. Acta Odontol Scand,1963,21:533-411.
  • 9Soo S, Leung T. Hidden clasps versus C clasps and I bars: a comparison of retention.J Prosthet Dent, 1996, 75:622-625.
  • 10King GE. Dual-path design for removable partial dentures. J Prosthet Dent,1978,39:392-395.

共引文献8

同被引文献35

引证文献4

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...