伴随社会主义经济的全面发展,我国对电力的需求量也增加,对供电配电的水平和质量有了更高的要求。但我国变电站依旧存在如电能质量差,功率因素低,无功功率分配不合理等状况。在此通过对东破变电站无功补偿装置改造,阐述无功补偿装置与技术的应用,满足变电站无功补偿,以提高输电设备的利用率,降低电力系统设备的损坏和有功网损,减少无功电能损失,从而提高东破变电站功率因素。
With the development of socialist economy, the power demand in China has also been increased, and the requirements fur the level and quality of power supply and distribution have been higher. But the problems such as poor substation power quality, low power factor, unreasonable reactive power distribution etc. still exist in our country. The reactive power compensation device of the east crushing transformer substation was transfurmed, and the application of reactive compensation device and technology was described, so that the reactive power compensation could be met to improve the utilization rate of transmission equipment, reduce the damage to power system equipment and active power loss, and reduce the reactive power loss, thereby improve the power factor of the east crushing
出处
《铜业工程》
CAS
2013年第4期71-73,共3页
Copper Engineering
关键词
无功补偿
电能损失
电网
电能质量
功率因素
控制器
reactive power compensation
electric energy loss
power grid
the quality of electric energy
power factor
controller