摘要
针对恒温恒湿空调运行的高能耗问题,设计了一种节能型恒温恒湿机组,机组结合了冷凝热回收装置-变容量系统等节能手段。本文针对恒温恒湿空调系统控制回路中温湿度之间的耦合作用,设计前馈补偿解耦器解除温湿度控制回路间的耦合关系,并用Matlab进行解耦仿真。结果表明加入解耦器后达到了解耦的控制效果,为温湿度控制提供了一种行之有效的方法。
According to the high energy consumption problems of the constant temperature and humidity air-conditioning opera- tion, designed a kind of energy-saving constant temperature and humidity unit, it use some way called condensation heat recovery unit-variable volume system to save the energy. Aiming at coupling between temperature and humidity of control loop in constant temperature and humidity air-conditioning system, designed a Feedforward compensation decoupling unit to release the coupling between temperature and humidity of control loop, and it simulation to decoupling by used Matlab. The results show that it achieve control effect of decoupling by used decoupling unit,it provides an effective method for temperature and humidity control.
出处
《流体机械》
CSCD
北大核心
2013年第8期72-77,57,共7页
Fluid Machinery
关键词
恒温恒湿
温湿度控制
解耦控制
PID控制
constant temperature and humidity
temperature and humidity control
decoupling eontrol
PID control