Evaluation of the systematic set-up errors using electronic portal image device in the radiotherapy procedures

放射治疗电子射野影像系统的系统摆位误差的评估(英文)
下载PDF
导出
摘要 Objective: The aim of this work was to quantify the extent of set-up errors to conduct a quality assurance (QA) aspect of treatment delivery, verification of the treatment field's position on different days using electronic portal. Methods: This study was carried out on 12 patients, treated for pelvis tumor; and total of 240 images obtained by electronic portal image device (EPID) were analyzed. The EPIs acquire using EPID attached to the Siemens linear accelerator. The anatomy match- ing software (Theraview) was used and displacement in two dimensions were noted for each treatment field to study patient setup errors. Results: The percentages of mean deviations less than 5 mm in X direction were 65% & 92%, from 5-10 mm were 31% & 19% and more than 10 mm were 11% & 9% forNP and lateral direction respectively. The percentages of mean deviations less than 5 mm in Y direction were 65% & 63%, from 5-10 mm were 33% & 28% and more than 10 mm were 22% & 29%. The mean deviations in 2D-vector errors were 〈 5 mm in 47% and 46%, 5-10 mm in 36% and 37% and 〉 10 mm in 37% and 37% of images in the NP and lateral direction respectively. Conclusion: The results revealed that the ranges of set up errors are immobilization method to improve reproducibility. The observed variations were not within the limits..
出处 《The Chinese-German Journal of Clinical Oncology》 CAS 2013年第9期439-442,共4页 中德临床肿瘤学杂志(英文版)
关键词 electronic portal imaging device (EPID) setup errors tumor control probability 图像设备 设置 评价系统 门户 电子 西门子直线加速器 放疗 平均偏差
  • 相关文献

参考文献11

  • 1Murthy KK, AI-Rahbi Z, Sivakumar SS, et al. Verification of setup er- rors in external beam radiation therapy using electronic portal imag- incl. J Med Phys, 2008, 33: 49-53.
  • 2International Commission on Radiation Units and Measurements, Prescribing, recording, and reporting photon beam therapy, ICRU Report, 50. Bethesda, MD: ICRU Publications, 1994.
  • 3International Commission on Radiation Units and Measurements. Prescribing, recording, and reporting photon beam therapy (Supple- ment to ICRU Report 50), ICRU Report, 62. Bethesda, MD: ICRU Publications, 2000.
  • 4Hurkmans CW, Remeijer P, Lebesque JV, et al. Set-up verification using portal imaging; review of current clinical practice. Radiother Oncol, 2001,58: 105-120.
  • 5Munro P. Portal imaging technology: past, present and future. Semin Radiat Oncol, 1995, 5: 115-133.
  • 6Kutcher G J, Coia. L, Gillin M, et al. Comprehensive QA for radiation oncology; report of AAPM Radiation Therapy Committee, Task Group 40. Med Phys, 19(34, 21: 581-618.
  • 7Khan FM. The physics of radiation therapy. 5th edition. Philadelphia: Lippincott Williams and Wilkins, 2003.
  • 8Hunt MA, Schulthesis TE, Desobry GE, et al. An evaluation of setup uncertainties for patients treated to pelvic sites. Int J Radiat Oncol Biol Phys. 1995. 32: 227-233.
  • 9Marks JE, Haus AG, Sutton HG, et aL The value of frequent verifica- tion films in reducing localization error in the irradiation of complex fields. Cancer, 1976, 37: 2755-2761.
  • 10International Commission on Radiation Units and Measurements (ICRU). Determination of absorbed dose in a patient irradiated by beams of X and gamma rays in radiotherapy procedures. ICRU Re- port No. 24, Washinqton DC. 1976.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部