摘要
该文介绍了高压单级离心鼓风机电容补偿容量的计算方法。通过对单级离心风机的特点分析,得出高压单级离心鼓风机电容补偿实际容量,以确定工程中要把握的若干要点,从而确保电容补偿给鼓风机带来的实际节能效果。
The article introduces the calculation method of capacitance compensation capacity of high-voltage single-stage centrifugal blower.According to the characteristic analysis of single-stage centrifugal blower,the article gives the practical capacitance compensation capacity of high-voltage single-stage centrifugal blower and determines several strong-points to be grasped in the projects so as to ensure the practical energy conservation effect archived by the capacitance compensation for blower.
出处
《城市道桥与防洪》
2013年第7期342-343,27,共2页
Urban Roads Bridges & Flood Control
关键词
单级离心风机
高压电容补偿
节能
single-stage centrifugal blower,high-voltage capacitance compensation,energy conservation