期刊文献+

局部狭窄幅度振荡弹性管内脉动流阻抗分析 被引量:5

ANALYSIS OF THE INPUT IMPEDANCE OF PULSATIVE FLOW THROUGH A VESSLE WITH MILD STENOSIS AMPLITUDE OSCILLAING RADIALLY
下载PDF
导出
摘要 本文研究局部缓慢狭窄幅度径向振荡血管内血液脉动流的输入阻抗。犬股动脉计算结果表明不论哪一种参数变化,零阶谐频阻抗模(阻力)最大,然后下降,在二阶谐频处发生波动。狭窄振荡频率的变化,使各阶谐频输入阻抗模在一个心动周期内发生不同的变化。狭窄幅度的变化则对输入阻抗模影响较小。 in this paper , the input impedance of a pulsative flow through a vessel with mild stenosis amplitude radically was investigated .The calculate of arteria femoralis of dog showed no matter which kind of stenosis parameters change ,the input impedance of the zero order harmonic frequency is the largest ,and the others reduce successively .There is a fluctuation when it comes to the second order harmonic frequency ,which accords with the physiology fact. The frequency of the stenosis amplitude oscillatory makes the input impedance periodically change in a cardiac cycle. But the character of the wall of the tube has little effect on the input impedance.
出处 《医用生物力学》 CAS CSCD 2000年第3期157-161,共5页 Journal of Medical Biomechanics
关键词 缓慢狭窄血管 狭窄幅度径向振荡 输入阻抗 vessel with mild stenosis , stenosis amplitude oscillating radially , input impedance
  • 相关文献

参考文献2

二级参考文献7

  • 1许世雄,上海力学,1982年
  • 2Young D F,J Biomechanics,1973年,6期,395-409,547-559页
  • 3Lee J S,J Appl Mech,1970年,29卷,9页
  • 4Young D F,J Engng Ind trans ASME,1968年,90卷,248页
  • 5吕岚,医用生物力学,1999年,14卷,143页
  • 6Lee J S,J Appl Mech,1970年,29卷,9页
  • 7Yong D F,J Engnd Ind trans ASME,1968年,90卷,248页

共引文献9

同被引文献37

  • 1李义凯,陈建华,邱桂春.脊柱推拿时咔哒声响的测量技术分析与设计[J].第一军医大学学报,2005,25(4):419-422. 被引量:7
  • 2许世雄,计琳,王庆伟.中医滚法推拿对血液流动影响的数值研究[J].应用数学和力学,2005,26(6):694-700. 被引量:29
  • 3陈文君,许世雄.推拿颈动脉窦降低体动脉压数学模型研究[J].上海生物医学工程,2006,27(2):70-73. 被引量:4
  • 4Shixiong X, Lin J,Yongtian C, et al. Numerical Investigation of Effect of Rolling Manipulation of Traditional Chinese Medical Massage on blood Flow [ A]. Applied Mathematics and Mechanics [ M] (will be published)
  • 5Lin J, Low HT, Chew YT,et al. Flow through a blood vessel with stenosis moving axially [ C ]. 2003 Summer Bioengineering Conference, June 25 - 29, Sonesta Beach Resort in Key Biscayne, Florida.
  • 6Berger SA,Jou LD. Flow in stenotic Vessels [J]. Annu Rev Fluid Mech,2002,32:347 -382.
  • 7Shixiong X,Juntao Y, Xinwen Z,et al. Pulsatile blood flow through a cylindrical tube with a mild stenosis axially[ c ]. 9th International Conferene on Biomedical Engineering December 3 -6 1997 ,Singapore.
  • 8Chakravarty S, Datta A, Mandal PK. Analysis of nonlinear blood flow in a stenosed flexible artery [ J ]. Int J Engng Sci, 1995,33(12): 1821 - 1837.
  • 9Yong DF. Effect of a time -dependent stenosis on flow through a tube [ J]. J England Ind Trans ASME, 1986,90:248.
  • 10Chakravarty S, Datta A, Mandal PK. Effect of body acceleration on unsteady flow of blood past a time - dependent artery stenosis [ J ]. Mathl Comput Modelling, 1996,24 (2): 57 - 74.

引证文献5

二级引证文献62

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...