期刊文献+

无托槽隐形矫治技术——现在和将来 被引量:10

Clear aligner treatment: Current and future
下载PDF
导出
摘要 本文主要从临床的角度,对现阶段无托槽隐形矫治技术的生物力学特征、对牙移动的控制以及对复杂病例的多矫治器联合治疗进行了分析和讨论,并对隐形矫治技术未来可能的发展或突破方向进行了探讨。 In this article, the biomechanical characteristics and tooth movement control of clear aligner were discussed, the treatment of complicated cases by combiningclear aligner withother materials is explained, and the future development or breakthrough of clear aligner is presented.
作者 陈嵩
出处 《国际口腔医学杂志》 CAS 2013年第5期561-564,共4页 International Journal of Stomatology
关键词 无托槽隐形矫治技术 生物力学 计算机辅助设计制造 clear aligner biomechanics computer aided design/computer aided making
  • 相关文献

参考文献3

  • 1Paquette DE. Clear aligner treatment[M]//Graber LW, Vanarsdall RL Jr, Vig KW. Orthodontics, current principles and techniques. 5th ed. Philadel- phia: Elsevier Mosby, 2011: 639-688.
  • 2Iwasaki LR, Haack JE, Nickel JC, et al. Human tooth movement in response to continuous stress of low magnitude[J]. Am J Orthod Dentofacial Orthop, 2000, 117(2): 175-183.
  • 3张宁,白玉兴,张昆亚,任超超,周洁珉,祁鹏.不同厚度热压膜材料的力学性能研究[J].北京口腔医学,2009,17(4):184-186. 被引量:20

二级参考文献14

  • 1Boyd RL, Miller R J, Vlaskalic V. The Invisalign System in adult orthodontics: mild crowding and space closure cases. J Clin Orthod 2000,34(4) :203-212.
  • 2Wong BH. Invisalign A to Z. Am J Orthod Dentofacial Orthop,2002, 121 (5) :521-524.
  • 3Kuo E, Miller RJ. Automated custom-manufacturing technology in orthodontics. Am J Orthod Dentofacial Orthop,2003,123 (5):578- 581.
  • 4Vlakalic V, Boyd RL. Clinical evolution of the Invisalign appliance. J Calif Dent Assoc,2002,30 (10) :769-776.
  • 5Bollen AM, Huang G, King G, et al. Activation time and material stiffness of sequential removable orthodontic appliances. Part 1: Ability to complete treatment. Am J Orthod Dentofacial Orthop,2003, 124 ( 5 ) :496-501.
  • 6Clements KM, Bollen AM, Huang G, et al. Activation time and material stiffness of sequential removable orthodontic appliances. Part 2 :Dental improvements. Am J Orthod Dentofacial Orthop, 2003,124 (5) :502-508.
  • 7GD Gardner, Dunn WJ, Taloumis L. Wear comparison of thermoplastic materials used for orthodontic retainers. Am J Orthod Dentofacial Orthop,2003,124 (3) :294-297.
  • 8Ryokawa H, Miyazaki Y, Fujishima A, et al. The mechanical properties of dental thermoplastic materials in a simulated intraoral environment. J Orthodontic Waves ,2006,65 ( 6 ) :64-72.
  • 9Tricca R, Chunha L. Properties of aligner material EX30. The Invisalign System,2006. 177-184.
  • 10Kusy RP. Orthodontic biomaterials: From the past to the present. Angle Orthod,2002,72(6) :501-512.

共引文献19