对"手动盘车法"和"电流法"两种常用电梯平衡系数的检测方法进行了介绍,并对常用方法无法对超低层无机房电梯检测的原因进行了分析,提出了超低层无机房电梯平衡系数的检测方法,实践证明:采用"手动盘车比较法"测定出的数据准确,值得推广。
This paper introduced the detection method of two common elevator balance coefficients of"manual turning method"and"current method",and analyzed the causes of commonly used method unable detect the ultra low layer inorganic room elevator,put forward the detection method of ultra low layer inorganic room elevator balance system,the practice proved: the determination data was accurate used"manual barring comparison method",worthy of promotion.
出处
《山西建筑》
2013年第27期219-220,共2页
Shanxi Architecture
关键词
电梯
平衡系数
检测方法
elevator
balance coefficient
detection method