期刊文献+

核电厂板式热交换器钛板穿孔分析 被引量:3

原文传递
导出
摘要 国内某核电厂新建机组(3号机组)在投运一年的时间内,常规岛闭式冷却水系统的板式换热器出现大量板片穿孔泄露事件,穿孔片数累计达239片。穿孔导致换热器除盐水侧与海水侧相通,
出处 《腐蚀科学与防护技术》 CAS CSCD 北大核心 2013年第5期442-444,共3页 Corrosion Science and Protection Technology
  • 相关文献

参考文献7

  • 1ASTM B 265-10. Standard Specification for Titanium and Titanium Alloy Strip, Sheet, and Plate [S]. American Society for Testing and Materials, 2010 ASTM E 2371-04.
  • 2Standard Test Method for Analysis of Titanium and Titanium ICP [S]. American Society for Testing and Materials, 2004 ASTM E 1409-08.
  • 3Standard Test Method for Determination of Oxy- gen and Nitrogen in Titanium and Titanium Alloys by the Inert Gas Fusion Technique [S]. American Society for Testing and Materials, 2008 ASTM E 1447-09.
  • 4Standard Test Method for Determination of Hy- drogen in Titanium and Titanium Alloys by the Inert Gas Fusion Thermal Conductivity/Infrared Detection Method [S]. American So- ciety for Testing and Materials, 2009.
  • 5GB/T228-2002,金属材料室温拉伸试验方法.2002.
  • 6付艳红,时铁彬,徐岩.含沙量测量方法及比较分析[J].东北水利水电,2010,28(9):35-36. 被引量:19
  • 7刘家俊.材料磨损原理及其耐磨性[M].清华大学出版社,1993.

共引文献18