摘要
文章介绍了对迁安热电公司1号机组投产后锅炉冷态上水方式不断探索的过程,该公司首先采用汽动给水泵前置泵替代电动给水泵,后来利用更经济的锅炉补水泵替代电动给水泵进行冷态上水,通过实际运行中的有关数据证实了两种方法的节能效果。
This article introduces exploration on unit 1 of cold state boiler water feeding scheme of Qianan thermoelectricity company. The company first alternates electric feed water pump booster pump to steam turbine feed water pump, then uses the boiler pump cold water feeding scheme. Through the actual operation of the relevant data, two ways energy conservation have been confirmed.
出处
《现代工业经济和信息化》
2013年第16期14-15,共2页
Modern Industrial Economy and Informationization
关键词
汽动给水泵前置泵
锅炉补水泵
锅炉冷态上水
经济性评价
booster pump of turbo-feed pump
boiler pump
cold state boiler water feeding scheme
economy evaluation