期刊文献+

循环流化床锅炉冷态临界流化风量与运行风量的关系分析 被引量:9

Analysis of the Relationship of CFBB Minimum Fluidization Air Flow in Cold and Hot Positions
下载PDF
导出
摘要 利用厄贡准则式和浙江大学提出的计算式计算了宽筛分颗粒的临界流化风速以及冷热态临界流化风速的比值,分析了冷态临界流化风量与热态运行时风量的关系,认为两者基本相当时才能保证热态运行时床料良好流化。 The minimum fluidization velocity umf of wide-grade coal and the ratio of umf in cold and hot positions were calculated using the Ergun and Zhejiang University's equations respectively. The rela- tionship of the umf in cold and hot positions was analyzed and from the analysis the conclusion that the cold and hot umf should be nearly the same to keep the CFB running properly can be drawn.
出处 《锅炉技术》 北大核心 2000年第11期5-8,共4页 Boiler Technology
关键词 循环流化床锅炉 冷态临界流化风量 运行风量 Circulating Fluidized Bed Boiler (CFBB) Minimum fluidized air flow in cold position Running fluidized air flow
  • 相关文献

参考文献2

共引文献3

同被引文献12

  • 1Chunbao Xu,J.-X. Zhu.EFFECTS OF GAS TYPE AND TEMPERATURE ON FINE PARTICLE FLUIDIZATION[J].China Particuology,2006,4(3):114-121. 被引量:6
  • 2上诲自动化仪表股份有限公司.SUPMAX800分散控制系统说明书及技术协议[K].2003.
  • 3上海自动化仪表股份有限公司.SUPMAX800分散控制系统说明书及技术协议[K],2003.
  • 4党黎军.循环流化床锅炉的启动调试及安全运行[M].
  • 5东方锅炉(集团)股份有限公司.440t/h超高压再热CFB锅炉调试说明书[K].
  • 6冯俊凯.锅炉原理及计算[M].北京:科学出版社,1979
  • 7屈卫东;杨建华.循环流化床锅炉设备及运行,2002.
  • 8岑可法,等.循环流化床锅炉的原理设计及运行[M].北京:中国电力出版社,1999.
  • 9李光华,徐正泉,何王全,吕怀安,马丽锦,高洪培,蒋敏华,孙献斌,张敏.NERC在循环流化床燃烧技术领域的研究与开发[J].热力发电,1999,28(2):10-14. 被引量:8
  • 10张晓杰,韩志华,刘文弘.临界流化速度的计算及应用[J].东北电力技术,1999,20(1):16-20. 被引量:6