期刊文献+

某单层厂房排架柱承载力鉴定

The capacity identification of a one- storied factory bent frame column
下载PDF
导出
摘要 本文以具体工程为例,介绍单层厂房排架柱承载力鉴定方法。针对A类建筑,通过修改地震分组实现对特征周期的调整;同时结合抗震鉴定承载力调整系数,采用等强代换法对混凝土排架柱配筋进行验算和分析。为同类结构的承载力鉴定提供一定的参考和指导。 On the basis of specific projects ,this paper introduced the method of the identification of bent frame column used in single storey factory. Class A buildings achieve the adjustment of Capacity identification by modifying the earthquake group; Combined with regulation factor of quake proof capacity identi fication, use equal strength replacement method to check and analysis the reinforcing bars of concrete bent frame column. It provides reference and guidance to the capacity identification of homogeneous structure.
作者 郑耀宗
出处 《福建建筑》 2013年第9期34-36,共3页 Fujian Architecture & Construction
关键词 排架柱 承载力鉴定 A类建筑 特征周期 抗震鉴定承载力调整系数 Bent frame column Capacity identification Class A building characteristic period Regulation factor of quake - proof capacity identification
  • 相关文献

参考文献5

  • 1GB50010--2010混凝土结构设计规范[S].
  • 2GB50009-2012,建筑结构荷载规范[S].
  • 3GB50023-2009,建筑抗震鉴定标准[S].
  • 4GB50011-2010,建筑抗震设计规范[S].
  • 5叶运烈,杨爱仪,张建平,等.全围常用标准图实物工程量手册[M].北京:中国计划出版社,1995.