期刊文献+

氚尾气处理中的浓度在线采集控制系统研究

Online System of Monitoring Tritium Concentration for Removing Waste Tritium Gas
下载PDF
导出
摘要 氚在军事、工业等领域中具有重要的作用,在氚尾气处理中的浓度采集与设备控制过程复杂。介绍了在分布式氚尾气处理设备中,氚浓度在线采集系统的原理和控制系统结构。采用工业控制计算机作为上位机负责数据的显示与存储,下位机负责数据的采集与控制,上位机与下位机均采用串口通信。系统实现了在线采集控制过程的智能化,由人机交互的界面软件完成对整个系统的管理。 Tritium plays an important role in military, industry and other fields. It is complex to obtain the concentration and control the equipment in removing waste tritium gas. The principles and structure of mo- nitoring system were introduced. To display and store the data in the industrial control computer as a host computer, the lower computer collects the data real-time and sends the control signal. Both of the host computer and lower computer are based on serial communication. The system realizes the intelligence of online collecting and controlling, and the man-machine interface manages all of the partial.
作者 杜阳 杨正益
出处 《四川兵工学报》 CAS 2013年第9期93-95,108,共4页 Journal of Sichuan Ordnance
基金 国家自然科学基金项目(20671065)
关键词 氚浓度 在线采集 控制系统 在线报警 tritium concentration online collection control system real-time alarm
  • 相关文献

参考文献6

二级参考文献46

  • 1李立武,文启彬.气体组分和气体同位素分析[J].质谱学报,1995,16(2):19-21. 被引量:3
  • 2褚效中,周亚平,周理,寇登民.气相色谱法分析氢同位素气体[J].分析化学,2006,34(5):629-632. 被引量:13
  • 3翁承文,姚琼英,候建平,邢丕峰,郭高品,付依备.低温热色谱分离氢同位素[J].高技术通讯,1996,6(4):52-56. 被引量:5
  • 4周俊波,高丽萍.高纯氘中杂质的低温气相色谱分析[J].原子能科学技术,2007,41(3):356-360. 被引量:9
  • 5DEGTYAREVA O F, BONDAREVA L T. Gaschromatographic analysis of mixtures of hydrogen isotopes[J]. J Anal Chem, 2004, 59 (5) : 442-446.
  • 6ZHOU Junbo, GAO Liping, WANG Kuisheng. Hydrogen isotope separation by cryogenic gas chromatography using the combined column of 5A molecular sieve and Al2O3 [J]. Intern J Hydrogen Energy, 2006, 2: 1-5.
  • 7WATANABE K, MATSUYAMA M, KOBA- YASHI T, et al. Gas-chromatographic separation of H2-D2 mixtures by Pd-Pt alloy near room temperature [J]. Journal of Alloys and Compounds, 1997, 257: 278-284.
  • 8陈迪 郭勇 刘艳秋.用于中子吸收剂量测量的组织等效电离室.辐射防护,1983,3(6):401-409.
  • 9ICRP 60号出版物[M].北京:原子能出版社,1993:35-44.
  • 10WATTS R T.The functional and performance requirements for tritium in air monitors provided at CANDU reactors and associated facilities for occupational radiation protection[J].Fusion Technology,1985,8:2 432-2 437.