摘要
分析了直流电机换向火花产生的主要原因,提出了如何对电磁部分和机械部分引起的火花进行检测,通过检测得到正确判断,进行恰当地调整,使电机运行状况得到改善。
The main factors of D. C. Motor commutation spark were discussed in this article. Furthermore, we discussed the methods how to detect the spark due to the electromagnetic and mechanical, so we could choose appropriate adjustments which improved the motor running status in a correct judgment on the basis of detecting.
出处
《四川兵工学报》
CAS
2013年第9期109-111,共3页
Journal of Sichuan Ordnance
关键词
直流电机
换向火花
检测
调整
D.C. Motor
commutation spark
detection
adjustment