介绍了多喷嘴对置式气化炉系统中所用的蒸发热水塔在日常运行中发生带水的可能原因,并对原因进行分析,从工艺优化和设备操作方面提出改进方法和措施。
Introduced evaporative hot water tower with opposed multi - burner gasifier system of the possible causes of water in daily operation, and the reason is analyzed, put forward the improvement methods and measures from the aspects of process optimization and equipment operation.
出处
《山东化工》
CAS
2013年第9期198-199,共2页
Shandong Chemical Industry
关键词
蒸发热水塔
带水
原因
处理
evaporative hot water tower
with water
cause
treatment