期刊文献+

肌电图监测在腰椎手术中的应用 被引量:6

下载PDF
导出
摘要 随着脊柱外科手术技术的飞速发展,高风险脊柱手术的增多,相关的术后并发症也随之而来,其中神经损伤是一项极为严重的术后并发症,国外一份108419例脊柱手术的回顾性调查显示,术后神经损伤发生率高达1%,而其中神经根损伤占了一半以上。即使通过术中x线透视常规检测,术后仍有较高的神经损伤发生率。为了加强术中对神经功能的监测,降低医源性神经损伤,20世纪70年代以来,一项简单、有效的新技术被广泛应用于脊柱外科——术中神经电生理监测。
作者 石磊 邓忠良
出处 《重庆医学》 CAS CSCD 北大核心 2013年第28期3450-3452,共3页 Chongqing medicine
  • 相关文献

参考文献21

  • 1Bose B, Wierzbowski LR, Sestokas AK. Neurophysiologicmonitoring of spinal nerve root function during instru-mented posterior lumbar spine surgery[J], Spine(Phila Pa1976),2002,27(13):1444-1450.
  • 2Holland NR,Kostuik JP. Continuous electromyographicmonitoring to detect nerve root injury during thoracolum-bar scoliosis surgery[J]. SpineCPhila Pa 1976),1997,22(21):2547-2550.
  • 3Uribe JS, Vale FL,Dakwar E. Electromyographic monito-ring and its anatomical implications in minimally invasivespine surgery[J]. SpineCPhila Pa 1976),2010,35(26 Sup-pl):S368-374.
  • 4Holland NR. Intraoperative electromyography [J]. J ClinNeurophysiol, 2002,19(5) : 444-453.
  • 5Leppanen RE,Abnm D. American society of neurophysio-logical monitoring, intraoperative monitoring of segmentalspinal nerve root function with free-run and electrically-triggered electromyography and spinal cord function withreflexes and F-responses. a position statement by the A-merican society of neurophysiological monitoring [ J]. JClin Monit Comput, 2005,19(6) :437-461.
  • 6Padberg AM,Thuet ED. Intraoperative electrophysiologicmonitoring: considerations for complex spinal surgery[J].Neurosurg Clin N Am,2006,17(3) : 205-226.
  • 7Suess O,Brock M,Kombos T. Motor nerve root monito-ring during percutaneous transforaminal endoscopic se-questrectomy under general anesthesia for intra- and ex-traforaminal lumbar disc herniation[J]. Zentralbl Neuro-chir,2005,66(4) :190-201.
  • 8Calancie B,Lebwohl N, Madsen P, et al. Intraoperative e-voked EMG monitoring in an animal model. A new tech-nique for evaluating pedicle screw placement [J]. Spine(Phila Pa 1976),1992,17(10):1229-1235.
  • 9Calancie B, Madsen P, Lebwohl N. Stimulus-evoked EMGmonitoring during transpedicular lumbosacral spine in-strumentation. Initial clinical results[J]. Spine(Phila Pa1976),1994,19(24):2780-2786.
  • 10Toleikis JR, Skelly JP, Carlvin AO, et al. The usefulnessof electrical stimulation for assessing pedicle screw place-ments[J]. J Spinal Disord,2000,13(4) :283-289.

二级参考文献13

  • 1Okuyama K, Abe E, Suzuki T, et al. Posterior lumbar interbody fusion: a retrospective study of complications after facet joint excision and pedicle screw fixation in 148 cases. Acta Orthop Scand, 1999, 70:329-334.
  • 2Thomsen K, Christensen FB, Eiskjaer SP, et al. The effect of pedicle screw instrumentation on functional outcome and fusion rates in posterolateral lumbar spinal fusions: a prospective, randomized clinical study. Spine, 1997, 22:2813-2822.
  • 3Welch WC, Rose RD, Balzer JR, et al. Evaluation with evoked and spontaneous electromyography during lumbar instrumentation: a prospective study. J Neurosurg, 1997, 87:397-402.
  • 4Darden BV 2nd, Wood KE, Hatley MK, et al. Evaluation of pedicle screw insertion monitored by intraoperative evoked electromyography. J Spinal Disord, 1996, 9:8-16.
  • 5Owen JH. The application of intraoperative monitoring during surgery for spinal deformity. Spine, 1999, 24:2649-2662.
  • 6Brown RH, Nash CL, Berilla JA, et al. Cortical evoked potential monitoring: a system for intraoperative monitoring of spinal cord function. Spine, 1984, 9:256-261.
  • 7Toleikis JR, Carlvin AO, Shapiro DE, et al. The use of dermatoma evoked responses during surgical procedures that use intrapedicular fixation of the lumbosacral spine. Spine, 1993, 18:2401-2407.
  • 8Owen JH, Padberg AM, Spahr-Holland L, et al. Clinical correlation between degenerative spine disease and dermatomal somatosensory-evoked potentials in humans. Spine, 1991, 16:S201-S205.
  • 9Glassman SD, Dimar JR, Puno RM, et al. A prospective analysis of intraoperative electromyographic monitoring of pedicle screw placement with computed tomographic scan confirmation. Spine, 1995, 20:1375-1379.
  • 10Weinstein JN, Spratt KF, Spendlger D, et al. Spine pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placements. Spine, 1988, 13:1012-1018.

共引文献12

同被引文献64

  • 1杨新宇,李书纲,翁习生,邱贵兴.术中体感诱发电位改善对颈椎病患者术后脊髓功能恢复的预测(英文)[J].中国临床康复,2005,9(18):218-219. 被引量:3
  • 2LIU Bai-yun,TIAN Yong-ji,LIU Wen,LIU Shu-ling,QIAO Hui,ZHANG Jun-ting,Jim Gui-jun.Intraoperative facial motor evoked potentials monitoring with transcranial electrical stimulation for preservation of facial nerve function in patients with large acoustic neuroma[J].Chinese Medical Journal,2007(4):323-325. 被引量:10
  • 3Bhagat S,Durst A,Grover H,et al.An evaluation of multimodal spinal cord monitoring in scoliosis surgery:a single centre experience of 354 operations[J].Eur Spine J,2015,http://dx.doi.org/10.1007/s00586-015-3766-8(Epub).
  • 4鲁祖能,曾庆杏.实用肌电图学[M].北京:人民卫生出版社,2000.136.
  • 5Sekimoto K,Nishikawa K,Ishizeki J,et al.The effects of volatile anesthetics on intraoperative monitoring of myogenic motor-evoked potential to transcranial electrical atimulation and on partial neuromuscular blockade during propofol/fentany/nitrous oxide anesthesia in humans[J].Neurosurg Anesthesiol,2006,18(2):106-111.
  • 6Kawaguchi M,Sakamoto,Ohnishi H,et al.Intraoperative myogenic motor evoked potentials induced by direct electrical stimulation of the exposed motor cortex under isoflurane and sevoflurane[J].Anesth Analg,1996,82(3):593-599.
  • 7Gavrancic B,Lolis A,Beric A.Author information.Train-offour test in intraoperative neurophysiologic monitoring:differences between hand and foot train-of-four[J].J Clin Neurophysiol,2014,31(6):575-579.
  • 8Kim WH,Lee JJ,Lee SM,et al.Comparison of motor-evoked potentials monitoring in response to transcranial electrical stimulation in subjects undergoing neurosurgery with partial vs no neuromuscular block[J].Br J Anaesthesia,2013,110(4):567-576.
  • 9Choi I,Hyun SJ,Kang JK,et al.Combined muscle motor and somatosensory evoked potentials for intramedullary spinal cord tumour surgery[J].Yonsei Med J,2014,55(4):1063-1071.
  • 10Shida Y,Shida C,Hiratsuka N,et al.High-frequency stimulation restored motor-evoked potentials to the baseline level in the upper extremities but not in the lower extremities under sevoflurane anesthesia in spine surgery[J].J Neurosurg Anesthesiol,2012,24(2):113-120.

引证文献6

二级引证文献40

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部