期刊文献+

冠状动脉磁共振成像进展 被引量:1

The progress of coronary magnetic resonance imaging
下载PDF
导出
摘要 冠状动脉性心脏病简称冠心病,是一类发病率和死亡率较高的疾病。该疾病的早期发现与治疗对于改善病人的生活质量和提高生存率有重要意义。磁共振成像以无创性、无电离辐射、具有良好的软组织对比度、多参数及任意层面成像等优势,逐渐被应用于冠状动脉成像检查。通过对冠状动脉磁共振成像的主要序列的归纳和分析,总结影响冠状动脉磁共振成像质量的各种因素,并比较各扫描序列与技术的优势及限度。 Coronary heart disease (CHD) is a kind of disease with high morbidity and mortality. The early detection and treatment has important significance to patient. With the features of noninvasive, no radiation, good soft tissue contrast and multi parameter, and displaying anatomy in arbitrary plane, magnetic resonance imaging (MRI) was gradually applied in coronary artery imaging. In this paper, the main sequence and scanning technology of coronary MRI were reviewed, factors that affecting the quality of coronary magnetic resonance imaging were summarized, and the main advantages and disadvantages were concluded.
出处 《国际医学放射学杂志》 2013年第5期453-455,共3页 International Journal of Medical Radiology
关键词 冠状动脉性心脏病 磁共振成像 成像方法 扫描技术 Coronary heart disease Magnetic resonance imaging Imaging method Scanning technology
  • 相关文献

参考文献7

二级参考文献73

  • 1程流泉,高元桂,孙玮,盛复庚,蔡幼铨.磁共振冠状动脉成像定位方法[J].中华放射学杂志,2003,37(11):1016-1020. 被引量:19
  • 2程流泉,高元桂,孙玮,盛复庚,盖鲁粤,蔡幼铨.屏气三维快速平衡稳态进动序列对冠状动脉狭窄的诊断效能[J].中华放射学杂志,2005,39(3):267-271. 被引量:20
  • 3程流泉,高元桂,马林,蔡幼铨,Wang Yi.呼吸导航回波触发冠状动脉磁共振成像[J].中国医学影像学杂志,2006,14(2):81-84. 被引量:13
  • 4常时新,郝楠馨,杜育杉,王葳,王轶彬,宗根林,汪波.3.0T高分辨率自由呼吸导航全心冠状动脉成像初步研究[J].临床放射学杂志,2006,25(11):1026-1030. 被引量:13
  • 5Manning WJ, Nezafat R, Appelbaum E, et al. Coronary magnetic resonance imaging. Cardiol Clin, 2007,25(1) : 141-170.
  • 6Keegan J, Gatehouse P, Yang GZ, et al. Coronary artery motion with the respiratory cycle during breath-holding and free-breathing: implications for slice followed coronary artery imaging. Magn Reson Med, 2002,47(3) :476-481.
  • 7Plein S, Jones TR, Ridgway JP, et al. Three-dimensional coronary MR angiography performed with subject-specific cardiac acquisition windows and motion adapted respiratory gating. AIR Am J Roentgenol, 2003,180(2) :505-512.
  • 8Tangcharoen T, Jahnke C, Koehler U, et al. Impact of heart rate variability in patients with normal sinus rhythm on image quality in coronary magnetic angiography. J Magn Reson Imaging, 2008, 28 (1) :74 79.
  • 9Stehning C, Bornert P, Nehrke K, et al. Free-breathing wholeheart coronary MRA with 3D radial SSFP and self-navigated image reconstruction. Magn Reson Med, 2005,54(2) :476 480.
  • 10Weber OM, Martin AJ, Higgins CB. Whole-heart steady state free precession coronary artery magnetic resonance angiography. Magn Reson Med, 2003,50(6) : 1223-1228.

共引文献24

同被引文献1

引证文献1

二级引证文献4

相关作者