摘要
目的:通过分析微量注射泵的检测方法、检测结果及检测过程中发现的问题,提出处理方案,以提高检测的准确率和效率。方法:通过检测使用中、新购置和维修后的微量注射泵,分析影响准确度的因素,总结出各环节应注意的问题,以提高检测结果的可靠性。结果:分析微量注射泵检测中出现的流量不准、报警不准及无法确定限值等原因,寻找解决方案,采取使用配套的注射器、新鲜的纯净水及定期清洗等方式,保障微量注射泵的量值准确。结论:微量注射泵的质量控制非常重要,只有严格执行检测规范,并注意排除影响准确度的各种因素,才能确保检测结果的准确性,为患者提供可靠的服务。
Objective: Through analyze the detecting method, detection result and problems of detection process of microinjection pump. we can propose solutions to improve the detection accuracy and efficiency. Methods: Through detection microinjection pump in new purchase and re air after, we can analyze the factors of influencing the accuracy. We can sum up the problems of every link to improve the reliability of detection. Results: Through analyze the inaccurate of test flow and alarm of the microinjection pump. We can take the following approach: use the special syringe, fresh water and regular cleaning. We can ensure the accuracy of themeasurement of the microinjection pump. Conclusion: Tl^e quality control of the microinjection pump is very iportant. Only strict implementing the standards and removing the factors of affecting the accuracy, we can ensure the detection results and provide reliable service for patients.
出处
《中国医学装备》
2013年第9期26-27,共2页
China Medical Equipment
关键词
微量注射泵
检测
质量控制
准确度
可靠性
Microinjection pump
Test
Quality control
Accuracy
Reliability