期刊文献+

改良蛙式矫治器远中移动上颌磨牙临床初探 被引量:2

Clinical research of modified Frog Appliance for upper molar distalization
原文传递
导出
摘要 目的:比较改良蛙式矫治器与摆式矫治器远中移动上颌磨牙的临床疗效。方法:将20例需远中移动上颌磨牙病例分成两组,改良蛙式矫治器组8例,摆式矫治器组12例。对矫治前及磨牙移动至中性关系后的头颅定位侧位片进行测量,并通过成组设计的t检验分析两组牙颌面形态变化的差异。结果:①改良蛙式矫治器组与摆式矫治器组在上颌第一磨牙远中移动距离、远中倾斜程度、矫治时间及速率上无明显统计学差异(P>0.05)。②改良蛙式矫治器组上颌第二前磨牙远中移动1.83±1.21 mm,远中倾斜7.50°±7.07°。摆式矫治器组上颌第二前磨牙近中移动1.79±2.44 mm,近中倾斜4.33°±3.73°。两组间有明显统计学差异(P<0.01)。③改良蛙式矫治器组上颌中切牙近中移动0.17±0.52 mm,远中倾斜0.58°±1.74°。摆式矫治器组上颌中切牙近中移动2.96±2.46 mm,近中倾斜7.08°±7.48°。两组间有明显统计学差异(P<0.05)。结论:改良蛙式矫治器能不依赖患者配合,有效地远中移动上颌磨牙,并且相比较摆式矫治器能有效地减少前牙支抗丧失,适用于安氏Ⅱ类错牙合畸形的矫治。 Objective:To compare the effects between modified Frog Appliance and pendulum on dentofacial morphol- ogy in upper molar distalization cases. Method:Twenty cases were divided into two groups. One group(n=8) had been treated with modified Frog Appliance and the other group (n=12) treated with pendulum. Cephalometric analysis was performed be- fore and after the treatment. The data were analyzed by using independent-samples t test. Result: (j]The distalized distance, tipped distally degree,the duration and the rate for the maxillmy first molar to achieve a Class i molar relationship between the modified Frog Appliance group and the pendulum group were not statistically significant (P 〉0.05). (~In the modified Frog Appliance group, tbe maxillary second premolars were distalized 1.83_+1.21 mm and tipped 7.50_+7.07~ distally. In the pendulum group, the maxillary second premolars moved 1.79+2.44 mm mesially and tipped 4.33_+3.73~ mesially. The differ- ence between the two groups were statistically significant (P 〈0.01). @In the modified Frog Appliance group, the maxillary incisors were advanced 0.17_+0.52 mm and tipped 0.58_+1.74~ distally. In the pendulum group,the maxillary incisors were advanced 2.96_+2.46 mm and proclined 7.08_+7.48~. The difference between the two groups were statistically significant (P 〈 0.05). Conclusion:Modified Frog Appliance can distalize the maxillary first molar effectively. However, compared with pendu- lum,the modified Frog Appliance has advantage of anchorage control. It is more fit to the con'ection of Class I1 malocclusion.
出处 《临床口腔医学杂志》 2013年第9期560-563,共4页 Journal of Clinical Stomatology
基金 上海市卫生局科研课题资助项目(054088)
关键词 远中移动 上颌磨牙 摆式矫治器 改良蛙式矫治器 upper molar distalization pendulum modified Frog Appliance
  • 相关文献

参考文献13

  • 1Erin ACS,Karin AS,Fang Q,et al. Comparison of soft-tissue profiles after treatment with headgear or Herbst appliance [J]. Am J Orthod Dentnfacial orthop,2008,133(4):509-514.
  • 2赵晓光,刘月华.摆形矫治器与直丝弓矫治器治疗安氏Ⅱ类骨性Ⅰ类错畸形的研究[J].华西口腔医学杂志,2005,23(2):138-141. 被引量:4
  • 3寻春雷,曾祥龙,王兴.正畸支抗的新手段:种植体支抗系统的发展和应用[J].口腔正畸学,2003,10(1):47-50. 被引量:22
  • 4Kinzinger G,Wehrbein H,Byloff FK,et ah Innovative Anchorage Al- ternatives for Molar Distalization-an Overview [J]. J Orofac Orthop, 2005,66(5) :397-413.
  • 5Ngantung V,Nanda RS,Bowman SJ. Posttreatment evaluation of the distal jet appliance[J]. Am J Orthod Dentofacial Orthop,2001,120(2): 178-185.
  • 6Runge ME,Martin JT,Bukai F. Analysis of rapid maxillary molar distal movement without patient cooperation[J]. Am J Orthod Dento- t:cial Orthop,1999,115(2):153-157.
  • 7Kinzinger GS,Fritz UB,Sander FG,et al. Efficiency of a pendulum ap- pliance for molar distalization related to second and third molar eruption stage[J]. Am J Orthod Dentofacial Orthop,2004,125(1):8-23.
  • 8Taner TE,Yukay F,Pehlivanoglu M,et al. A comparative analysis of maxillary tooth movement produced by cervical headgear and pend-x appliance[J]. Angle Orthod, 2003,73(6):686-691.
  • 9Gelgor BE,Buyulkylmaz T,Karaman AY,et al. Intraosseous Screw- Supported Upper Molar Distalization [J]. The Angle Orthodontist, 2003,74(6):838-850.
  • 10Haas SE,Cisneros GJ. The Goshgarian transpalatal bar:a clinical and an experimental investigation[J]. Semin Orthod,2000,6(2):98-105.

二级参考文献58

  • 1[1]Gainsforth BL, Higley LB. A study of orthodontic anchorage possibilities in basal bone. Am J Orthod Oral Surg 1945 ; 31 : 406-416
  • 2[2]Roberts WE, Smith RK, ZIlberman Y, Mozsary PG, Smith RS. Osseous adaptation to continuous loading of rigid endosseous implants. Am J Outhod. 1984;86(2):95-111.
  • 3[3]Celenza F, Hochman MN. Absomute anchorage in orthodontics:direct and indirect implant-assisted modalities. J Clin Orthod. 2000;34(7) :397-402
  • 4[4]Costa A, Raffaini M, Melsen B. Miniscrews as orthodontic anchorage: a preliminary report. Int J Adult Orthod Orthognath Surg 1998; 13: 201-9.
  • 5[5]Bae SM, Park HS, Kyung HM, Kwon OW, Sung JH. Clinical application of micro-implamt anchorage. J Clin Orthod. 2002; 36(5) :298-302
  • 6[6]Wehrbein H, Feifel H, Diedrich P. Palatal implant anchorage reinforcement of posterior teeth: A prospective study. Am J Orthod Dentofacial Orthop. 1999; 116(6): 678-86.
  • 7[7]JCO Interviews: Dr. Junji Sugawara on the skeletal anchorage system. J Clin Orthod. 1999;33:689-696.
  • 8[8]Glatzmaier J, Wehrbein H, Diedrich P. Biodegradable implants for orthodontic anchorage. A preliminary biomechanical study. Eur J Orthod. 1996 Oct; 18(5): 465-9.
  • 9[9]Wehrbein H, Diedrich P. Endosseous titanium implants during and after orthodontic load-an experimental study in the dog. Clin Oral Implants Res 1993;4:76-82.
  • 10[10]Saito S, Sugimoto N, Morohashi T, Ozeki M, Kurabayashi H,Shimizu H, Yamasaki K, Shiba A, Yamada S, Shibasaki Y. Endosseous titanium implants as anchors for mesiodistal tooth movement in the beagle dog. Am J Orthod Dentofacial Orthop.2000 Dec;118(6) :601-7.

共引文献24

同被引文献14

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部