摘要
首先对运行电抗及其影响因素作了描述并介绍了国外有关运行电抗的研究结果 ,然后通过理论分析与实测结果 ,得到了既简单又精度高的描述电弧炉运行电抗的关系式。最后 ,作为实例 ,将研究结果应用于某 10 0 t钢包精炼炉 ,可节电 3.8%。
The operating reactance of electric arc furnace and the related influencing factors are discribed and some research results abroad are introduced. Through theoretical analysis and practical measurements,a formula describing operating reactance with simple form and high accuracy is deduced.As an example,the research result is applied to a 100 t ladle furnace with 3.8% electric energy saving.
出处
《工业加热》
CAS
2000年第5期31-34,共4页
Industrial Heating
关键词
电弧炉
电抗
短路试验
供电
炼钢
electric arc furnace
reactance
short circuit test
electric supply