摘要 Investigations are reported into the use of an electromagnetically convoluted arc,external to a magnetic field(B-field)producing coil,in combination with a parallel R,L,C resonant circuit for interrupting quasi-steady currents.In order to elucidate the complex interactions between the arc,B-field and R,L,C circuit,the B-field producing coil is energised independently from the current to be interrupted and the R,L,C circuit.Experimental results are presented for the time variation of the currents flowing through the arc gap,the B-field coil and the parallel R,L,C circuit,along with the voltage across the arc gap.An insight is gained into the role of various effects,which are produced by the complex interactions and which might be used to advantage for direct current interruption. Investigations are reported into the use of an electromagnetically convoluted arc, external to a magnetic field (B-field) producing coil, in combination with a parallel R, L, C resonant circuit for interrupting quasi-steady currents. In order to elucidate the complex interac- tions between the arc, B-field and R, L, C circuit, the B-field producing coil is energised independently fi:om the current to be interrupted and the R, L, C circuit. Experimental results are presented for the time variation of the currents flowing through the arc gap, the B-field coil and the parallel R, L, C circuit, along with the voltage across the arc gap. An insight is gained into the role of various effects, which are produced by the complex interactions and which might be used to advantage for direct current interruption.
出处 《高电压技术》 EI CAS CSCD 北大核心 2013年第9期2166-2172,共7页 High Voltage Engineering
关键词 RLC电路 稳态电流 中断 相互作用 调查报告 谐振电路 磁场 线圈 Arc discharges ablation current interruption magnetic fields plasma arc devices plasma control
  • 相关文献

参考文献5

  • 1Nakao H, Nakagoshi Y, Hatano M, et al. Current interruption in HVDC SF6 gas MRTB by means of self-excited oscillation superimposition[J]. IEEE Transactions on Power Delivery, 2001, 16(4): 687-693.
  • 2Shiba Y, Morishita Y, Kaneko S, et al. Study of D.C. circuit breaker of H2-N2 gasmixture lbr high voltage[J]. Electrical Engineering in Japan, 2011, 174(2): 9-17.
  • 3Ryan H M. High voltage engineering and testing[M]. 3^nd edition. UK: Institution of Engineering and Technology (IET), 2013.
  • 4Zhang J R, Jones G R, Ma Z, et al. Interaction of helical arc devices with intercon- nected networks[J], lEE Proceedings of Generation, Transmission and Distribution,1996, 143(1): 89-95.
  • 5Shpanin L M, Jones G R, Humphries J E, et at. Current interruption using electro- magnetically convolved electric arcs in gases[J]. IEEE Transactions on Power Delivery, 2009, 24(4): 1924-1930.