摘要
某公司因扩大生产,其生产废水的水质和水量发生了较大变化,原处理构筑物难以满足处理要求。基于废水水质特点,采用IC+AO+BIOFOR处理技术并在原构筑物基础上进行工程扩建,工艺系统运行稳定,出水水质达到《污水综合排放标准》(GB 8978—1996)的一级标准。
Due to the great change in the quality and quantity of the lactic acid production wastewater from a chemical company in Jiangxi Province,the original treatment structures could not to meet the discharge standard.Based on the wastewater quality,IC + AO + BIOFOR treatment technologies were used,and the original treatment structures were expanded.The results showed that the expansion project was operated stably.The effluent quality met the first class criteria specified in Integrated Wastewater Discharge Standard (GB 8978-1996).
出处
《中国给水排水》
CAS
CSCD
北大核心
2013年第18期127-129,133,共4页
China Water & Wastewater
基金
江西省自然科学基金资助项目(2010GQC0132)
江西省科技厅"节能减排"示范项目(2010AE00200)
关键词
乳酸废水
扩建工程
IC
BIOFOR
lactic acid production wastewater
expansion project
IC