摘要 使用 PI- C感光材料分辨力测定仪 ,测定了感光材料分辨力。测定试验不仅证明感光材料分辨力测定仪操作稳定可靠、重复性好 ,而且测定实验加深了对感光材料的感光影象特性的研究。实验表明 ,最佳焦面实际集中在各种胶片乳剂层表层。 The resolving power of a photographic material can be determined by using of a PI C type resolution determinator.The determination experiments not only prove that the operation of the resolution determinator is reliable and repeatability is good,but also deepen the research on the properties of photographic image.The experiments show that the optimal focal plane is focused at the surface layer of the photographic emulsion.
出处 《光电工程》 CAS CSCD 2000年第6期52-54,共3页 Opto-Electronic Engineering
关键词 分辨力测量 感光材料 焦面 Resolution measurement Sensitive materials Focal plane
  • 相关文献