期刊文献+

CNG站脱水装置节能监测方法探讨

Discussion on the energy-saving monitoring method of dehydration unit in CNG station
下载PDF
导出
摘要 针对CNG加气站脱水装置无法满足节能监测标准相关测试条件,通过对脱水装置工作原理、电加热器能量转换过程的分析,找到了一种新的加热器电能利用率测试途径,并给出了相关参数的测试方法,有效地解决了标准测试方法无法操作的难题。通过现场试验,该方法应用效果良好,对今后CNG加气站的节能监测工作有着重要的指导意义。 Because the dehydration unit in CNG station can not meet the requirements of energy-saving monitoring standard,a new testing principle for electric energy utilization rate of electric heater has been found,and the testing method for relevant parameter has been provided by analyzing the principle of dehydration unit and the energy conversion process of electric heater.This method is able to effectively solve the difficult problems that the traditional method can not operate.The results of field testing showed that the applied effects of the method are better.It is important to guide the work of energy-saving monitoring in CNG station in future.
出处 《石油石化节能》 2013年第9期1-2,59,共2页 Energy Conservation in Petroleum & PetroChemical Industry
关键词 CNG加气站 脱水装置 电能利用率 CNG gas-filling station Dehydration unit Electronic energy utilization rate
  • 相关文献

参考文献1

  • 1全国能源基础与管理标准化技术委员会.工业电热设备节能监测方法[S]北京:中国标准出版社,1995.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部