Estimating extreme temperature differences in steel box girder using long-term measurement data 被引量:5

Estimating extreme temperature differences in steel box girder using long-term measurement data
下载PDF
导出
摘要 The extreme temperature differences in fiat steel box girder of a cable-stayed bridge were studied.Firstly,by using the long-term measurement data collected by the structural health monitoring system installed on the Runyang Cable-stayed Bridge,the daily variations as well as seasonal ones of measured temperature differences in the box girder cross-section area were summarized.The probability distribution models of temperature differences were further established and the extreme temperature differences were estimated with a return period of 100 years.Finally,the temperature difference models in cross-section area were proposed for bridge thermal design.The results show that horizontal temperature differences in top plate and vertical temperature differences between top plate and bottom plate are considerable.All the positive and negative temperature differences can be described by the weighted sum of two Weibull distributions.The maximum positive and negative horizontal temperature differences in top plate are 10.30 ℃ and -13.80 ℃,respectively.And the maximum positive and negative vertical temperature differences between top plate and bottom plate are 17.30 ℃ and-3.70 ℃,respectively.For bridge thermal design,there are two vertical temperature difference models between top plate and bottom plate,and six horizontal temperature difference models in top plate. The extreme temperature differences in flat steel box girder of a cable-stayed bridge were studied.Firstly,by using the long-term measurement data collected by the structural health monitoring system installed on the Runyang Cable-stayed Bridge,the daily variations as well as seasonal ones of measured temperature differences in the box girder cross-section area were summarized.The probability distribution models of temperature differences were further established and the extreme temperature differences were estimated with a return period of 100 years.Finally,the temperature difference models in cross-section area were proposed for bridge thermal design.The results show that horizontal temperature differences in top plate and vertical temperature differences between top plate and bottom plate are considerable.All the positive and negative temperature differences can be described by the weighted sum of two Weibull distributions.The maximum positive and negative horizontal temperature differences in top plate are 10.30°C and13.80°C,respectively.And the maximum positive and negative vertical temperature differences between top plate and bottom plate are 17.30°C and 3.70°C,respectively.For bridge thermal design,there are two vertical temperature difference models between top plate and bottom plate,and six horizontal temperature difference models in top plate.
出处 《Journal of Central South University》 SCIE EI CAS 2013年第9期2537-2545,共9页 中南大学学报(英文版)
基金 Project(51178100)supported by the National Natural Science Foundation of China Project(1105007001)supported by the Foundation of the Priority Academic Development Program of Higher Education Institute of Jiangsu Province,China Project(3205001205)supported by the Teaching and Research Foundation for Excellent Young Teachers of Southeast University,China
关键词 structural health monitoring cable-stayed bridge steel box girder temperature difference extreme value analysis 测量数据 钢箱梁 温差 估计 概率分布模型 结构健康监测系统 温度差异 横截面面积
  • 相关文献

参考文献18

  • 1WILLIAM G W,SHOUKRY S N,RIAD M Y.Study of thermal stresses in skewed integral abutment steel girder bridges[J].Structural Engineering International,2012,22(3):308-317.
  • 2SUBRAMANIAM K V,KUNIN J,CURTIS R,STREETER D.Influence of early temperature rise on movements and stress development in concrete decks[J].Journal of Bridge Engineering,2010,15(1):108-116.
  • 3TONG M,THAM L G,AU F T K,LEE P K K.Numerical modelling for temperature distribution in steel bridges[J].Computers and Structures,2001,79(6):583-593.
  • 4SONG Z W,XIAO J Z,SHEN L M.On temperature gradients in high-performance concrete box girder under solar radiation[J].Advances in Structural Engineering,2012,15(3):399-415.
  • 5LARSSON O,KAROUMI R.Modelling of climatic thermal actions in hollow concrete box cross-sections[J].Structural Engineering International,2011,21(1):74-79.
  • 6KENNEDY J B,SOLIMAN M H.Temperature distribution in composite bridges[J].Journal of Structural Engineering-ASCE,1987,113(3):475-482.
  • 7LIU H B,CHEN Z H,ZHOU T.Theoretical and experimental study on the temperature distribution of H-shaped steel members under solar radiation[J].Applied Thermal Engineering,2012,37:329-335.
  • 8CAO Y H,YIM J,ZHAO Y,WANG M L.Temperature effects on cable stayed bridge using health monitoring system:A case study[J].Structural Health Monitoring-An Intemational Journal,2011,10(5):523-537.
  • 9ROBERTS-WOLLMAN C L,BREEN J E,CAWRSE J.Measurements of thermal gradients and thcir cffects on segmental concrete bridge[J].Journal of Bridge Engineering,2002,7(3):166-174.
  • 10XU y L,CHEN B,NG C L,WONG K Y,CHAN W Y.Monitoring temperature effect on a long suspension bridge[J].Structural Control & Health Monitoring,2010,17(6):632-653.

二级参考文献2

共引文献23

同被引文献33

引证文献5

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部