摘要
在液体闪烁分析中各种淬灭均会影响到 DPM 测量的准确性及样品同的可比性。本文介绍一种 DPM 测量方法一效率示踪法,并根据在各种不同条件下的实验数据证明:效率示踪法是一种准确而有效的 DPM 测量方法。
In liquid scintillation analysis varioius quench can affect accuracy of DPM measurement and comparison in the samples.This paper introduces a DPM measurement methed-the Efficiency Tracing method.The experiment results urnder the different condition indicate that the Efficienct Tracing method is a accurate and powerful method of calculating DPM.
出处
《东北师大学报(自然科学版)》
CAS
CSCD
1991年第3期45-48,共4页
Journal of Northeast Normal University(Natural Science Edition)
关键词
效率示踪法
液体闪烁分析
DPM
Efficiency Tracing method
Liquid seintillation analysis
DPM