期刊文献+

克石化公司常减压装置E1001腐蚀失效分析

Analysis for Corrosion Leakage of Atmospheric and Vacuum Distillation Unit E1001 Applied in Karamay Petrochemical Company
下载PDF
导出
摘要 中石油克拉玛依石化分公司常减压蒸馏I套装置的常顶换热器管束自投用以来曾多次发生腐蚀泄漏。我们从失效管束材质的数据分析调查,找出失效管束发生腐蚀原因,并提出相关建议,避免类似失效事件的再次发生。 At present, there has been a wide occurrence of corrosion leakage of overhead heat exchangers tubes in the atmospheric and vacuum distillation unit since it is applied in Karamay Petrochemical Company. To solve this problem, an investigation has been carried out to find out the cause for the leakage on the basis of analyzing the data with regard to the materials of disabled tubes. Finally, a related suggestion has been put forward to prevent the corrosion failure from happening again.
出处 《全面腐蚀控制》 2013年第9期46-48,60,共4页 Total Corrosion Control
关键词 腐蚀 换热器 管束 泄露 corrosion heat exchangers tubes leakage
  • 相关文献

参考文献1

二级参考文献26

  • 1傅晓萍.蒸馏装置塔顶缓蚀剂技术现状[J].石油化工腐蚀与防护,2005,22(2):15-18. 被引量:9
  • 2汪实彬,刘家国,崔新安,封子文,王进刚.加工塔河油电脱盐技术研究[J].炼油技术与工程,2005,35(10):23-26. 被引量:6
  • 3李庆梅,袁瑞森,徐晓.“一脱四注”与“一脱二注”——蒸馏塔顶系统工艺防腐蚀技术概论[J].石油化工腐蚀与防护,1996,13(4):33-35. 被引量:6
  • 4侯芙生.加工劣质原油对策讨论[J].当代石油石化,2007,15(2):1-6. 被引量:34
  • 5孙家孔.石油化工装置设备腐蚀与防护手册[M].北京:中国石化出版社,1996.286-316.
  • 6梁文杰.石油化学[M].东营:石油大学出版社,2005.
  • 7David W. A. Nile D. C. Corrosion inhibitors for crude distillation columns[J]. Materials Performance, 2003, 42(5): 44-49.
  • 8Mishal S. A. Faisal M. A. Olavo C. D. Damage mechanism and corrosion control in crude unit overhead line[J]. Hydrocarbon Asia, 2003, Mar./Apr.44-49.
  • 9Gray M. R. Eaton P. E. Le T. Inhibition and promotion of hydrolysis of chloride salts in model crude oil and heavy oil[J]. Petroleum Science and Technology, 2008, 26: 1934-1944.
  • 10Londono Y. Mikula R. Eaton P. et al. Interaction of chloride salts and Kaolin clay in the hydrolysis of emulsified chloride salt at 250-350℃ [J]. Petroleum Science and Technology, 2009, 27: 1163-1174.