以本质安全型无源救灾电话电路为例,分析了该电路在不同本质安全试验电气原理等效图下的安全火花试验过程,指出火花试验装置应接入被试电路中可能产生最大火花能量的试验点上,才能保证本质安全型电路通过火花试验后有足够的安全系数。
Taking an intrinsic safety circuit of passive rescue telephone as an example, the paper analyzed test process of safe spark test of the circuit under different electrical principle equivalent diagrams of intrinsic safety test, and indicated that spark apparatus should be connected into test points which maybe produce the highest spark energy in the tested circuit, which can ensure intrinsic safety circuit has enough safety factor after passing spark test.
出处
《工矿自动化》
北大核心
2013年第10期114-116,共3页
Journal Of Mine Automation
关键词
本质安全型电路
ib等级
无源救灾电话
电气原理等效图
最高开路电压
最大短路电流
intrinsic safety circuit
ib level
passive rescue telephone
equivalent diagram of electricalprinciple
maximum open-circuit voltage
maximum short-circuit current