期刊文献+

钢板固定治疗胫骨平台骨折的临床疗效 被引量:2

The clinical efficacy of steel plate fixation treating on tibial plateau fractures
下载PDF
导出
摘要 目的观察钢板内固定治疗胫骨平台骨折的临床疗效。方法对46例胫骨平台骨折患者根据不同骨折类型行单侧钢板(24例)和双侧钢板(22例)内固定治疗,术后指导患者功能锻炼。随访观察骨折复位情况,主要参考正、侧位x线片进行评估。结果患者均获随访,时问10~42(22.2±9.8)个月。单侧及双侧钢板内固定治疗愈合时间分别为17.8周±6.3周、19.7周±6.9周,x线结果显示,单侧钢板有13例、双侧钢板有11例获得满意的关节面复位。结论钢板内固定治疗胫骨平台骨折临床疗效满意。 Objective To observe the clinical efficacy of steel plate fixation treating tibial plateau fractures. Meth- ods 46 patients received different operation according to the tibial plateau fractures types, 24 patients received Uni- lateral steel plate and the rest 22 patients received standard dual plate fixation. Patients were guided with functional exercises after the operation and all patients were followed up after discharge to evaluate functional recovery, using X- ray to check reduction of the fracture. Results All patients were followed up for 10 - 42 (22. 2 ± 9. 8) months, the recovery time of the unilateral steel plate and standard dual plate fixation were respectively ( 17. 8 ± 6. 3 ) weeks, ( 19. 7 ± 6. 9 )weeks, according to the results of X ray, there were 13 cases obtained satisfactory joint reduction in the unilateral plate group, in the dual plate group were 11 cases. Conclusions The clinical effcacy of steel plate fixation treating tibi"al plateau fractures is satisfactory.
作者 程中午
出处 《临床骨科杂志》 2013年第5期549-551,共3页 Journal of Clinical Orthopaedics
关键词 单侧钢板 双侧钢板固定 胫骨平台骨折 unilateral steel plate dual plate fixation tibial plateau fractures
  • 相关文献

参考文献5

二级参考文献25

共引文献89

同被引文献18

  • 1胡飞,尚希福,姚刚.双钢板治疗复杂胫骨平台骨折[J].临床骨科杂志,2013,16(1):70-72. 被引量:33
  • 2Rommens P M,EI Attal R,Hansen M,et al.Intramedullary nailing of proximal tibial fractures[J].Oper Orthop Traumatol,2011,23(5):411-422.
  • 3Rademakers M V,Kerkhoffs G M,Sierevelt IN,et al.Operative treatment of 109 tibial plateau fractures:five-to 27-year follow-up results[J].J Orthop Trauma,2007,21(1);5-10.
  • 4Mustonen A O,Koskinen S K,Kiuru M J.Acute knee trauma:analysis of multidetector computed tomography findings and comparison with conventional radiography[J].Acta Radiol,2005,46(8):866-874.
  • 5Nikolaou V S,Tan H B,Haidukewych G,et al.Proximal tibial fractures:early experience using polyaxial locking-plate technology[J].Int Orthop,2011,35(8):1215-1221.
  • 6Schutz M,Sudkamp N P.Revolution in plate osteosyn-thesis ? new internal fixator systems[J].J Orthop Sci,2003,8(2):252-258.
  • 7Spagnolo R,Pace F.Management of the Schatzker VI fractures with lateral locked screw plating[J].J Am Acad Orthop Surg,2011,19(11):690-700.
  • 8Weaver M J,Harris M B,Strom A C,et al.Fracture pattern andfixation type related to loss of reduction in bicondylar tibial plateau fractures[J].Injury,2012,43(6):864-869.
  • 9Egol K A,Tejwani N C,Capla E L,et al.Staged management of high energy proximal tibia fractures(OTA types 41):the results of a prospective,standardized protocol[J].J Orthop Trauma,2005,19(7):448-455.
  • 10Hu YL,Ye F G,Ji A Y,et al.Three-dimensional computed tomography imaging increases the reliability of classification systems for tibial plateau fractures[J].Injury,2009,40(12):1282-1285.

引证文献2

二级引证文献11