期刊文献+

生物传感器在环境分析中的研究现状与前景 被引量:2

Advance and prospect of biosensor research on environmental analysis
下载PDF
导出
摘要 在环境控制中 ,生物传感器作为广谱装置应用于废水或生化需氧量的检测 ,特异性地对农药、重金属、硝酸盐、亚硝酸盐、除草剂和次氮基乙酸等环境污染物进行检测。讨论了各类生物传感器 (酶生物传感器、全细胞生物传感器、受体传感器和免疫传感器 )在环境分析中的应用实例及其优缺点 。 Biosensors for environmental controlling have been developed either as broad-spectrum devices, such as for measurement of biochemical oxygen demand in industrial effluents and other waste water or for analyte-specific determination of pesticides, groups of pesticides, heavy metals, nitrate, nitrite, nitrilotriacetic acid, or herbicides. Many examples of biosensors(i.e. enzyme sensors, whole-cell biosensors, receptor-based biosensors and immunosensors) applied to environmental analysis are presented with their advantages and disadvantages discussed here. Also, the problems to be resolved immediately of biosensor research in environmental analysis are pointed out to serve as a starting point for information about trends and to encourage more research in this interdisciplinary field.
出处 《生物技术通讯》 CAS 2000年第4期309-314,共6页 Letters in Biotechnology
关键词 生物传感器 环境 农药 分析 biosensor environment pesticide enzyme
  • 相关文献

参考文献28

  • 11.Kramer MP. Biosensors for measuring pesticides residues in the environment:past, present and present. J AOAC Int,1996,79(6):1245
  • 22.Zuern A & Mueller H. Photolithographically patterned enzyme membranes for t hedetection of pesticides and copper(2) based on enzyme inhibition. Anal Chem,1993,346(6?9):589
  • 33.Fernando JC, Rogers KR, Anis NA et al. Rapid detection of antic holinesteraseinsecticides by a reusable light addressable potentiometric biosen sor. Agri FoodChem,1993,41(3):511
  • 44.Larsen LH, Revsbech NP & Binnerup SJ. A microsensor for nitrate based on immobilized denitrifying bacteria. App Env Microbiol, 1996,62(4):1248
  • 55.Heitzer A, Malachowsky K, Thonnard JE et al. Optical biosenso r for environmentalon?line monitoring of naphthalene and salicylate bioavailab ility with an immobilizedbioluminescent catabolic reporter bacterium. Appl Env Microbiol,1994,60(5):1487
  • 66.Willardson BM, Wilkins JF, Rand TA et al. Development and testi ng of a bacterialbiosensor for toluene?based environmental contaminants.Appl Env Microbiol,1998,64(3):1006
  • 77.Sticher P, Jaspers MCM, Stemmler K et al. Development and chara cterization of awhole?cell bioluminescent sensor for bioavailable middle?chai n alkanes in contamminatedgroundwater samples. App Env Microbiol,1997,63(10 )4053
  • 88.Pandard P & Rawson DM. An amperometric algal biosensor for herbicide detect ionemploying a carbon cathode oxygen electrode. Env Toxicol Water Quality,1 993,8(3):323
  • 99.Rella R, Ferrara D, Barison G et al. High?temperature operatin g biosensor for thedetermination of phenol and related compounds. Biotechnol Appl Biochem,1996,24:83
  • 1010.Konig A, Zaborosch C, Muscat A et al. Microbial sensors for paph thaleneusing Sphingomonas sp. B1 or Pseudomonas fluorescens WW4. Appl Microbiol Biotechnol,1996,45(6):844

同被引文献14

引证文献2

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部