期刊文献+

均流器均匀送风的实验研究 被引量:1

Experimental study on uniform air supply by flow equalizers
下载PDF
导出
摘要 应用测压管测压原理,研制了送风均流器,并进行了实体实验。结果显示该均流器能明显改变送风管路特性;均流器均匀送风管路中,风口风量由主风管截面静压和均流器获得的动压转变而成的静压共同决定;均流器均匀送风的距离远大于常规风阀调节均匀送风的送风距离。 Based on the piezometer pressure measuring principle, develops an equalizer for air supply, and performs the experiment on the prototype of the equalizer. The results show that the equalizer can change the characteristics of air supply ducts observably, in the uniform air supply with equalizers, the air rate is determined by the static pressure in main duct and changed from velocity pressure intercepted by equalizers, and the distance of air supply with equalizers is much larger than that with air valve.
出处 《暖通空调》 北大核心 2013年第10期122-125,共4页 Heating Ventilating & Air Conditioning
关键词 送风均流器 静压 动压 送风距离 送风管路 特性 air supply equalizer, static pressure, velocity pressure, air supply distance, air supply pipe, characteristic
  • 相关文献

参考文献6

  • 1杨晚生,张吉光,韩海涛.静压式均匀送风道送风机理分析[J].广东工业大学学报,2005,22(1):110-114. 被引量:4
  • 2谢军龙,马银红.地铁空调送风风道出风均匀性数值模拟研究[C]//中国制冷学会2009年学术年会论文集,2009.
  • 3江世涣.风量分配器的试验研究[J].暖通空调,1993,22(3):7-9. 被引量:6
  • 4钟星灿,高慧翔.均匀送排风设计原理再探[J].暖通空调,2007,37(10):58-61. 被引量:14
  • 5Hua Jinjing, Ouyang Qin, Wang Yiran, et al. A dynamic air supply device used to produce simulated natural wind in an indoor environment[J]. Building and Environment, 2012,47(2): 349-356.
  • 6Djunaedy E, Cheong K W D. Development of a simplified technique of modelling four-way ceiling air supply diffuser[J]. Building and Environment, 2002, 37(4) : 393-403.

二级参考文献5

共引文献19

同被引文献4

引证文献1