期刊文献+

Performances of super-long span prestressed cable-stayed bridge with CFRP cables and RPC girder 被引量:1

Performances of super-long span prestressed cable-stayed bridge with CFRP cables and RPC girder
下载PDF
导出
摘要 To discuss the applicability of advanced composite carbon fiber reinforced polymer(CFRP) and ultrahigh performance concrete reactive powder concrete(RPC) in super-long span cable-stayed bridges, taking a 1 008 m cable-stayed bridge with steel girders and steel cables as an example,a new cable-stayed bridge in the same span with RPC girders and CFRP cables was designed,in which the cable's cross section was determined by the principle of equivalent cable capacity and the girder's cross section was determined in virtual of its stiffness, shear capacity and local stability. Based on the methods of finite element analysis,the comparative analysis of these two cable-stayed bridge schemes about static performances,dynamic performances,stability and wind resistance behavior were carried out. The results showed that it was feasible to form a highly efficient,durable concrete cable-stayed bridge with RPC girders and CFRP cables and made its applicable span range expand to 1 000 m long around. To discuss the applicability of advanced composite carbon fiber reinforced polymer (CFRP) and ultra- high performance concrete reactive powder concrete (RPC) in super-long span cable-stayed bridges, taking a 1 008 m cable-stayed bridge with steel girders and steel cables as an example, a new cable-stayed bridge in the same span with RPC girders and CFRP cables was designed, in which the cable' s cross section was determined by the principle of equivalent cable capacity and the girder' s cross section was determined in virtual of its stiffness, shear capacity and local stability. Based on the methods of finite element analysis, the comparative analysis of these two cable-stayed bridge schemes about static performances, dynamic performances, stability and wind resis- tance behavior were carried out. The results showed that it was feasible to form a highly efficient, durable concrete cable-stayed bridge with RPC girders and CFRP cables and made its applicable span range expand to 1 000 m long around.
出处 《Engineering Sciences》 EI 2013年第5期70-76,共7页 中国工程科学(英文版)
基金 National Natural Science Foundation of China(No.51078134) Natural Science Foundation of Jiangxi Province(No.20114BAB206010) Department of Education Foundation of Jiangxi Province(No.GJJ11449)
  • 相关文献

参考文献4

二级参考文献70

共引文献109

同被引文献7

引证文献1

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部