摘要 利用自行研制的错流式气液膜接触器及其膜吸收法烟气脱硫中试装置,以原海水作为吸收剂,针对火电厂燃煤机组排放的实际烟气,开展了烟气处理量为1 000Nm3/h的膜法海水脱硫中试试验研究.主要考察了海水和烟气流量、烟气SO2浓度对脱硫效率的影响;开展了中试装置稳定运行试验、技术经济分析和环境影响分析.结果表明:膜吸收法海水烟气脱硫技术经济优势明显,环境友好,应用前景广阔. A comprehensive investigation of the self-developed pilot plant for flue gas desulfurization was carried out, in which the flue gas was from coal-fired power generating unit and the absorbent was raw seawater. Meanwhile, the processing capacity of the pilot plant was about 1 000 Nm3/h. In the present work, the effects of various factors on desulfurization efficiency were considered, such as sea water and flue gas flow, SO2 concentration in flue gas. Furthermore, the running stability, technical economics evaluation and environmental impact of the pilot plant were studied. In addition, the results indicate that the membrane gas absorption for seawater flue gas desulfurization is of obvious technical and economic superiority and environment friendly, which has great potential in environmental protection fields.
出处 《膜科学与技术》 CAS CSCD 北大核心 2013年第5期73-77,共5页 Membrane Science and Technology
基金 2008海洋公益性行业科研专项经费项目(200805033)
关键词 膜吸收 膜接触器 海水烟气脱硫 membrane absorption membrane contactor seawater flue gas desulfurization
  • 相关文献

参考文献4

二级参考文献12

  • 1薛娟琴,王召启,洪涛,李伟达.中空纤维膜吸收烟气二氧化硫[J].广东化工,2005,32(6):8-10. 被引量:7
  • 2Klaassen R. Achieving flue gas desulphurization with membrane gas absorption[J]. Filtr & Sep, 2003, 40 (10) : 26-28.
  • 3Mohebi S, Mousavi S M, Kiani S. Modeling and simula- tion of sour gas membrane-absorption system: Influence of operational parameters on species removal[J]. J Nat- ural Gas Sei and Eng, 2009, 1(6) : 195-204.
  • 4Ashrafizadeh S N, Khorasani Z. Ammonia removal from aqueous solutions using hollow-fiber membrane contactors[J]. Chem Eng J, 2010,162(1) : 242-249.
  • 5Dindorea V Y,Brilmanc D W F,Versteegb G K Model- ling of cross-flow membrane contactors: physical mass transfer processes[J]. J Membr Sci, 2005,251 (1 - 2): 209-222.
  • 6Iversen S B, Bhatia V K, DaNm-Johansen K, et al. Characterization of microporous membranes for use in membrane contactors[J]. J Membr Sci, 1997, 130 (1 - 2) :205- 217.
  • 7Kreulen H, Smolders C A, Verstee G F. Micro-porous hollow fiber membrane modules as gas-liquid contactors Part2. Mass transfer with chemical reaction [J]. J Membr Sci, 1993, 78(3): 217-238.
  • 8Matsuda N, Sakai K, Yamamoto K, et al. Effects of hollow fiber packing fraction on blood flow pattern and gas transfer rate of an intravascular oxygenator (IVOX) [J]. J Membr Sci, 2000, 179(1-2) :231-241.
  • 9熊丹柳,邓修,戴干策.含浸液膜烟气脱硫试验[J].高校化学工程学报,1998,12(1):33-38. 被引量:7
  • 10金美芳,曹义鸣,邢丹敏,李晖,孙晓珊,杨丹.膜吸收法脱除二氧化硫[J].膜科学与技术,1999,19(3):44-46. 被引量:34

共引文献22

同被引文献217

引证文献18

二级引证文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部