期刊文献+

基于神光Ⅲ主机装置的中子半影锥成像系统设计 被引量:3

Design of diagnostic system for neutron penumbral imaging based on Shenguang-Ⅲfacility
下载PDF
导出
摘要 针对半影孔加工和检测困难的缺点,设计了半影锥成像系统。根据神光Ⅲ主机装置中子产额条件,确定成像系统排布参数;根据点扩展函数的尖锐性和等晕性要求,确定半影锥参数;模拟半影锥系统的分辨率,以及在不同加工精度、偏心误差、旋转误差和物距误差时,对成像质量的影响。模拟结果表明,系统分辨率能达到15μm,半影锥椭圆度的加工误差要小于0.1,瞄准的偏心误差要小于60μm,旋转误差要控制在0.35mrad以内,物距误差要控制在1mm以内。 The aperture for neutron penumbral imaging is newly designed in order to reduce the difficulties of fabrication and detecting. Firstly, the source-detector and source-aperture distances are fixed on because of the neutron yield of Shenguang-Ⅲ facility. Then, base on the sharpness and isoplanaticity of the point spread function, the radii of the aperture are optimized. Finally, the resolution of the system is analysed, and the distortions induced by the aperture-fabrication error and misalignment are es- timated by the simulation. According to the results, a resolution of 15 μm can be satisfied, the fabrication error should be limited to a maximum of 0.1, the precision of alignment should be better than 60μm, the aperture rotation should be within 0.35 mrad, and the source-aperture distance error should be less than 1 ram.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2013年第10期2604-2610,共7页 High Power Laser and Particle Beams
基金 国家自然科学基金项目(11205142)
关键词 中子成像 半影锥 MONTE CARLO方法 瞄准精度 neutron imaging penumbra cone Monte Carlo method alignment precision
  • 相关文献

参考文献18

  • 1Landen O I J, Edwards J, Haan S W,et al. Capsule implosion optimization during the indirect-drive National Ignition Campaign[J]. Phys Plasmas. 2011, 18: 051002.
  • 2Morgan G L, Berggren R R, Bradley P A, et al. Development of a neutron imaging diagnostic for inertial confinement fusion experiments [J]. RevSei Instrum, 2001, 72(1): 865-868.
  • 3Bradley P A, Wilson D C, Swenson F J, et al. ICF ignition capsule neutron, gamma ray, and high energy x-ray images[J].Rev Sci In- strum, 2003, 74(3): 1824-1827.
  • 4Murphy T J, Barnes C W, Berggren R R, et al. Nuclear diagnostics for the National Ignition Facility[J]. Rev Sci Instrum, 2001, 72(1) : 773- 779.
  • 5Ress D, Lerche R A, Ellis R J, et al. Neutron imaging of laser fusion targets[J]. Science, 1988, 241 : 956- 958.
  • 6Ress D, Lerche R A, Ellis R J, et al. Neutron imaging of inertial confinement fusion targets at Nova[J] . Rev Sci Instrum, 1988, 59(8) : 1694-1696.
  • 7Disdier L, Rouyer A, Fedotoff A, et al. Neutron imaging of ICF target plasmas[J]. RevSci Inslrum, 2003, 74(3): 1832-1836.
  • 8Disdier L, Rouyer A, I,antu-joul I, et al. Inertial confinement fusion neutron images[J]. PhysPlasmas, 2006, 13: 056317.
  • 9Grim G P, Day R D, Clark D D, et al. Neutron imaging for inertial confinement fusion experiments[C]//Proc of SPIE. 2007: 67070H.
  • 10Disdier L, Rouyer A, Wilsonb D C, et al. High-resolution neutron imaging of laser imploded DT targets[J]. Nucl Instrum Methods Phys ResA, 2002, 489: 4,96-502.

二级参考文献14

  • 1陈法新,郑坚,杨建伦.中子厚针孔成像数值模拟研究[J].物理学报,2006,55(11):5947-5952. 被引量:15
  • 2Delage O,Garconnet J P,Schirmann D, et al. Neutron penumbral imaging of inertial confinement fusion targets at Phebusa[J]. Rev Sci In- strum, 1995,66(2) : 1205-1209.
  • 3Morgan G L, Berggren R R,Bradley P A, et al. Development of a neutron imaging diagnostic for inertial confinement fusion experiments[J]. Rev Sci Instrum ,2001,72(1) 1865-868.
  • 4Glebov V Y, Meyerhofer D D, Sangster T C, et al. Development of nuclear diagnostics for the National Ignition Facility[J]. Rev Sci Instrum, 2006,77 : 10E715.
  • 5Wilson D C,Grim G P,Tregillis I L, et al. Modeling the National Ignition Facility neutron imaging system[J]. Rev Sci Instrum, 2010,81: 10D335.
  • 6Murphy T J,Barnes C W, Berggren R R, et al. Nuclear diagnostics for the National Ignition Facility[J]. Rev Sci Instrum,2001,72(1):773- 779.
  • 7Ress A, Lerehe R A, Ellis R J, et al. Neutron imaging of inertial confinement fusion targets at Nova[J]. Rev Sci Instrum, 1988,59(8) :1694- 1696.
  • 8Disdier L, Rouyer A, Wilson D C, et al. High resolution neutron imaging of laser imploded DT targets[J]. Nuclear Instruments and Methods in Physics Research A, 2002,489 : 496 -502.
  • 9Disdier L,Rouyer A,Fedotoff A,et al. Neutron imaging of ICF target plasmas[J]. Rev Sci Instrum ,2003,74(3):1832- 1836.
  • 10Ress A,Lerche R A,Bourgade J L,et al. Capillary detector with denterated scintillator for inertial confinement fusion neutron images[J].Rev Sci Instrum ,2004,75(6) :2134-2139.

共引文献5

同被引文献40

  • 1赵宗清,丁永坤,刘东剑,唐昶环,温树槐,蒲以康.中子半影成像的数值模拟[J].强激光与粒子束,2006,18(7):1203-1207. 被引量:9
  • 2郝轶聃,缪文勇,赵宗清,袁永腾.中子半影成像中椭圆度误差的解析计算[J].强激光与粒子束,2007,19(3):507-510. 被引量:1
  • 3WilkeM D,BathaSH,BradleyPA,etal.TheNationalIgnitionFacilityneutronimagingsystem[J].RevSciInstrum ,2008,79:10E529.
  • 4RessD,LercheRA,EllisRJ,etal.Neutronimagingoflaserfusiontargets[J].Science,1988,241:956-958.
  • 5DisdierL,RouyerA,FedotoffA,etal.NeutronimagingofICFtargetplasmas[J].RevSciInstrum ,2003,74(3):1832-1836.
  • 6DisdierL,RouyerA,LantuéjoulI,etal.Inertialconfinementfusionneutronimages[J].PhysPlasmas,2006,13:056317.
  • 7CaillaudT,LandoasO,BriatM,etal.Developmentofthelargeneutronimagingsystemforinertialconfinementfusionexperiments[J].RevSciInstrum ,2012,83:033502.
  • 8GrimGP,GulerN,MerrillFE,etal.Nuclearimagingofthefuelassemblyinignitionexperiments[J].PhysPlasmas,2013,20:056320.
  • 9VolegovP,DanlyCR,FittinghoffDN,etal.NeutronsourcereconstructionfrompinholeimagingatNationalIgnitionFacility[J].RevSciInstrum,2014,85:023508.
  • 10MurphyTJ,BarnesC W,BerggrenRR,etal.NucleardiagnosticsfortheNationalIgnitionFacility[J].RevSciInstrum ,2001,72(1):773-779.

引证文献3

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题