收敛计恒张力控制精度是直接影响测量精度的主要因素,通过理论计算与测量精度分析,为确定收敛计恒张力参数提供了可靠的依据,且提出了提高收敛计测量精度的主要技术途径。
The precision of tape- extensometer′ s constant tension is the main factor to affect measure precision. Through theoretical calculation and measure precision,it provides a reliable basis to determine the parameter of tape- exten- someter’ s constant tension.Lastly,a technical approach to advance tape- extensometer's measure precision is pointed out.
出处
《岩土工程技术》
2000年第4期208-212,共5页
Geotechnical Engineering Technique
关键词
收敛计
恒张力
测力误差
测量精度分析
变形监测
tape- extensometer:constant tension
ergometer Error
precision analysis
techniqual approach