期刊文献+

正常小鼠冠状动脉的超声成像技术分析 被引量:1

Analysis of coronary artery imaging in healthy mice with echocardiography
下载PDF
导出
摘要 目的探讨利用高频小动物心脏超声对C57BL/6小鼠冠状动脉进行评价的可行性,为小鼠冠状动脉相关疾病动物模型的制备及其功能评价提供依据。方法采用Vevo 770型高分辨小动物超声仪,频率30 mHz的宽频探头,对20只健康C57BL/6小鼠于4、8和12周龄时冠状动脉的情况进行观察。测定和分析不同周龄小鼠冠状动脉内径值的变化。结果全部20只小鼠超声均成功检测到冠状动脉。超声心动图显示小鼠4周龄时左冠状动脉主干内径检测值为0.36±0.02 mm,右冠状动脉主干内径值为0.29±0.03 mm;8周龄时左冠状动脉主干内径值为0.38±0.06 mm,右冠状动脉主干内径值为0.37±0.02(mm);12周龄时左冠状动脉主干内径值为0.38±0.02 mm,右冠状动脉主干内径值为0.39±0.03 mm。结论利用高频小动物心脏超声可获取正常小鼠清晰的冠状动脉图像,并能准确反映小鼠冠状动脉内径值动态变化。为小鼠冠状动脉疾病模型的制备及其功能评价提供依据。 Objective To assess the feasibility of coronary artery in C57BL/6 mice With a high frequency ultrasound system and to provide evidence for preparation the murine model of KD. Methods Totally 20 mice were chosen and Visualsonics Vevo 770 UBM was used in this study. On weeks 4, 8 and 12, the developmental changes and dimensions of coronary artery of the mice were measured by echocardiography. Results By echocardiography, the present study successfully detected coronary artery diameter in the routine model of KD. On week 4, the diameter of left coronary artery in the mice was 0. 32 ~0. 14 mm, and the diameter of right coronary artery was 0.37 ~0. 02 mm, On week 8, the diameter of left coronary artery in the mice was O. 38 ~ 0. 06 ram, and the diameter of right coronary artery was 0. 37 ~ 0. 02 mm; on week 12, the diameter of left coronary artery in the mice was 0. 38 ~ 0. 02 ram, and the diameter of right coronary artery was 0. 39 +0.03 mm. Conclusions The the diameter of coronary artery in the mice coronary arteries disease. present study successfully could be measured which detected coronary arteries by way be benefit for the study echocardiography, and in the murine model of
出处 《中国比较医学杂志》 CAS 2013年第9期27-30,共4页 Chinese Journal of Comparative Medicine
基金 国家自然基金面上项目(81274109 30973238) 北京自然科学基金B类/北京教育委员会重大科研项目(KZ201010025024) 北京市教育委员会科技创新平台项目(PXM2011_014226_07_000085) 北京市卫生系统高层次卫生技术人才培养计划项目(2009-3-38)
关键词 超声心动图 小鼠 冠状动脉 Echocardiography Murine Coronary artery
  • 相关文献

参考文献8

  • 1陈植,刘俊峰,杜忠东,万岁桂,关云谦.粒细胞集落刺激因子对川崎病小鼠模型内皮祖细胞及其冠状动脉损伤的影响[J].中华儿科杂志,2012,50(10):788-792. 被引量:5
  • 2Siri FM, Jelicks LA, Leinwand LA, et al. Gated magnetic resonance imaging of normal and hypertrophied murine hearts [J]. Am J Phy-siol, 1997 272 (5pt2) : H2394 - H2402.
  • 3Coatney RW. Ultrasound imaging: principles and applications in rodent research[J]. ILAR J, 2001 42(3) : 233 - 247.
  • 4Lewis JS, Achilefu S, Garbow JR, et al. Small animal imaging. Current technology and perspectives for oncological imaging[ J ]. EurJ Cancer. 2002 38(16) : 2173 -2188.
  • 5Foster FS. Zhang MY, Zhou Y Q, et al. A new ultrasound instrument for in vivo micro-imaging of mice [ J ]. Ultrasound Med Biol, 2002 28(9) : 1165 -1172.
  • 6Collins KA, Korcarz CE. Lang RM. Use of echocardiography for the phenotypic assessment of genetically altered mice [ J ]. Physiol Genomics, 200 13 (3) :227 - 239.
  • 7Scherrer- Crosbie M, Steudel W, Hunziker P R, et al. Determination of right ventricular structure and function in normoxic and hypoxic mice: a transesophageal echocardiographic study[ J]. Circulation, 1998 98 (10) : 1015 - 1021.
  • 8方喜业.《医学实验动物学》.人民卫生出版社.第一版,p177.

二级参考文献2

共引文献4

同被引文献13

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部