摘要
基于流态重构节能型循环流化床锅炉于2008年通过国家鉴定以来,结合国家TSG G0002-2010《锅炉节能技术监督管理规程》,由中国特种设备检测研究院国家锅炉压力容器质量监督检测中心对9台流化床锅炉进行了能效测试,本文对锅炉产品特点与测试结果进行汇总分析,体现产品节能效果。
The CFB boiler with overlow emission based on fluidization state reconstruction has passed the appraisal by National Technology Department since 2008. Combining the document for TSG GO002 - 2010《Supervision Administration Regulation on Energy Conservation Technology for Boiler》, the 9 CFB boilers are tesced in energy efficiency by National Boiler &Pressure Vessel Quality Supervision and Test Enter of Special Equipments Inspection and Test Institute of China. The characteristic and test result of boiler product are analyzed and concluded. The energy conservation effect of product is proved in this paper.
出处
《节能技术》
CAS
2013年第5期450-453,共4页
Energy Conservation Technology
关键词
流态重构
循环流化床锅炉
能效测试
fluidization state reconstruction
CFB Boiler
energy efficiency test