期刊文献+

污废水预处理试验研究

Research on Acrylonitrile-butadiene-styrene (ABS) Resin Wastewater treatment with Electro-Fenton Process
下载PDF
导出
摘要 通过对酸性污废水进行预处理,研究电芬顿氧化对废水中有毒难降解特征污染物的分解转化能力.试验研究表明:在给定的条件下,当Fe2+离子浓度为0.6 mmol/L时,电芬顿氧化法对该废水的COD去除率最高,达到45.62%;电芬顿氧化能分解转化废水中大量的污染物. The wastewater from the condensing and drying section of aerylonitrile-butadiene-styrene(ABS) resin manufacturing was pretreated by Electro-Fenton, and the decomposition and transformation of the toxic and refractory typic pollutants was studied seriously. The results show that the COD removal efficiency was the highest of 45.62% with the iron concentration of 0.6 mmol/L. And a plenty of aromatic pollutants in the ABS resin wastewater were decomposed or tranformed efficiently by Elentro-Feton.
作者 韦海浪
机构地区 西北工业大学
出处 《渭南师范学院学报》 2013年第9期62-66,共5页 Journal of Weinan Normal University
关键词 污废水 电芬顿法 降解 wastewater electro-Fenton degradation
  • 相关文献

参考文献11

  • 1赖波,周岳溪,宋玉栋,席宏波,孙力东,程家运.一种定性分析ABS生产废水中溶解性有机物的方法[J].光谱学与光谱分析,2011,31(3):784-788. 被引量:15
  • 2胡成生,王刚,吴超飞,李平,韦朝海.含甲醛毒性废水电-Fenton试剂氧化技术研究[J].环境科学,2003,24(6):106-111. 被引量:39
  • 3Brillas E,Boye B,Banos M A,et al.Electrochemical degradation of chlorophenoxy and chlorobenzoic herbicides in acidic aqueous medium by the peroxi-coagulation method[J].Chemophere,2003,51:227-235.
  • 4解清杰,马涛,王琳玲,陆晓华.六氯苯污染沉积物的电Fenton法处理[J].华中科技大学学报(自然科学版),2005,33(3):122-124. 被引量:15
  • 5Shen Z,Yang J,Hu X,et al.Duelelectrodes oxidation of dye wastewater with gas dif fusion cathode[J].Environ Sci Technol,2005,39:1819-1826.
  • 6Yuan S H,Lu X H.Comparison treatment of various chlorophenols by electro-Fenton method:relationship between chlorine content and degradation[J].Journal of Hazardous Materials,2005,118 (1-3):85-92.
  • 7Yuan S H,Tian M,Cui Y P,et al.Treatment of nit rophenols by cathode reduction and Electro-Fenton methods[J].J Hazard Mater,2006,137:537-580.
  • 8Wu G M,Yuan S H,Huang Y H,et al.Degradation mechanism of indole by anodic oxidation and electro2Fenton[J].Huazhong University of Science and Technology(Nature Science Edition),2007,35:126-128.
  • 9Jin Anotai,LU ming-chun.Parichat Chewpreecha.Kinetics of aniline degradation by Fenton and electro-Fenton processes[J].Water Research,2006,40(9):1841-1847.
  • 10Ugur Kurt,Omer Apaydin,Talha Gonullu M.Reduction of COD in wastewater from an organized tannery industrial region by Electro-Fenton process[J].Journal of Hazardous Materials,2006,143 (1-2):402-408.

二级参考文献31

共引文献62

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部