摘要
针对机组高压加热器水管频繁泄漏问题,分析了进行高压加热器改造的必要性,介绍了高加改造方案,并对改造后的经济性进行了分析计算,以期对同类型机组改造提供一定的借鉴和指导。
According to frequent leakage problem of the high pressure heater, introduces the improvement of high pressure heater and analyzes the necessity of the improvement. Economical efficiency were analyzed and calculated in this paper.It has more universal guiding significance to the same type of generating unit.
出处
《江西电力职业技术学院学报》
CAS
2013年第2期36-37,共2页
Journal of Jiangxi Vocational and Technical College of Electricity
关键词
高压加热器
隔板
技术改造
high pressure heater
clapboard
technology improvement