期刊文献+

疏水性中空纤维膜的臭氧曝气传质试验 被引量:2

Experiment for Mass Transfer in Ozone Aeration with Hydrophobic Hollow Fiber Membrane
下载PDF
导出
摘要 对疏水性中空纤维膜有泡曝气进行了试验研究,得到了疏水性中空纤维膜的泡点,以及臭氧在pH=6和pH=8的水中的自分解系数,考察了疏水性中空纤维膜在不同pH水中的臭氧传质特性。试验表明疏水性中空纤维膜泡点较低;臭氧在pH=6的水中的自分解系数为0.036 min^(-1),在pH=8的水中为0.070 min^(-1);臭氧容积传质系数K_La值与曝气流量成正相关关系,在曝气流量相同时,pH=8条件下的臭氧K_La值约高出pH=6条件下0.1 min^(-1)。该研究为将来疏水性中空纤维膜在水处理厂的设计应用提供了一定依据。 Bubble aeration of hydrophobic hollow fiber membrane was studied. Bubble point of hydrophobic hollow fiber membrane was gained, and the decomposition coefficient of ozone in the water of pH=6 and pH=8 was also obtained. Ozone mass transfer prop- erties of hydrophobic hollow fiber membrane in different pH values were investigated. The results indicate that bubble point of hy- drophobic hollow fiber membrane is low, the decomposition coefficient of ozone is 0.036 min-1 in the water of pH=6 and is 0.070 min-l in the water of pH=8. There is a positive correlation between aeration air flux and volumetric mass transfer coefficient of ozone-KLa, when aeration air fluxes are same, KLa value of ozone in the water of pH=8 is about 0.1 min^-1 greater than that in the water of pH=6. This experiment provides a certain basis for the application of hydrophobic hollow fiber membrane in water treatment plant in the future.
出处 《净水技术》 CAS 2013年第5期77-81,共5页 Water Purification Technology
基金 国家科技重大专项"水体污染控制与治理"课题(2012ZX07408001)
关键词 疏水性 中空纤维膜 PH值 曝气流量 容积传质系数 hydrophobicity hollow fiber membrane pH value aeration air flux volumetric mass transfer coefficient
  • 相关文献

参考文献10

  • 1于万波,周集体,于得贤,陆际麟.臭氧-生物活性炭工艺处理有机微污染原水[J].净水技术,2003,22(6):20-23. 被引量:7
  • 2周云,李富生,汤浅晶.日本柴岛净水厂深度处理工艺[J].净水技术,2002,21(3):25-28. 被引量:5
  • 3张金松,范洁,乔铁军.臭氧-生物活性炭工艺的设计与运行管理[J].供水技术,2007,1(1):46-49. 被引量:14
  • 4高京伟.引黄水源水臭氧接触反应器结构和运行参数优化研究[D].北京:清华大学,2011.
  • 5桑军强,张锡辉,孟庆宇.水处理中的无泡供氧技术[J].中国给水排水,2003,19(11):25-28. 被引量:7
  • 6Jansen R.H.S.,de Rijk J.W.,Zwijnenburg A.,et al.Hollow fiber membrane contactors-A means to study the reaction kinetics of humic substance ozonation[J].Journal of Membrane Science,2005,257(1-2):48-59.
  • 7Atchariyawut S.,Phattaranawik J.,Leiknes T.,et al.Application of ozonation membrane contacting system for dye wastewater treatment[J].Separation and Purification Technology,2009,66(1):153-158.
  • 8Bampemg S.,Suwannachart T.,Atchariyawut S.,et al.Ozonation of dye wastewater by membrane contactor using PVDF and PTFE membranes[J].Separation and Purification Technology,2010,72(2):186-193.
  • 9Ho Hung Lai,Chan Wai Kit,Blondy A.,et al.Experiment and modeling of advanced ozone membrane reactor for treatment of organic endocrine disrupting pollutants in water[J].Catalysis Today,2012,193(1):120-127.
  • 10Kukuzaki M.,Fujimotob K.,Kaib S.,et al.Ozone mass transfer in an ozone-water contacting process with Shirasu porous glass (SPG) membranes-A comparative study of hydrophilic and hydrophobic membranes[J].Separation and Purification Technology,2010,72(3):347-356.

二级参考文献23

  • 1王建平,何元春.南洲水厂处理工艺优化运行分析[J].给水排水,2006,32(5):23-26. 被引量:12
  • 2乔铁军,安娜,尤作亮,张金松.梅林水厂臭氧/生物活性炭工艺的运行效果[J].中国给水排水,2006,22(13):10-13. 被引量:48
  • 3王晓昌.新修订的日本生活饮用水水质标准[J].给水排水,1994,20(3):16-17.
  • 4[4]中国城市供水协会.城市供水行业2010年技术进步发展规划及2020年远景目标[M].北京:中国建筑工业出版社,2005.
  • 5Tariq Ahmed, Michael J Semmens, Michael A Voss. Energy loss characteristics of parallel flow bubbleless hollow fiber membrane aerators[J ]. J Membrane Sci, 2000, 171(1)-87-96.
  • 6Tariq Ahmed, Michael J Semmens. Use of sealed end hollow fibers for bubbleless membrane aeration: experimental studies[ J ]. J Membrane Sci, 1992,69(1-2) : 1 - 10.
  • 7Peter T Weiss, Bryan T Oakley, John S Gulliver, et al.Bubbleless fiber aerator for surface waters[J ]. Journal of Environmental Engineering, 1996,122 (7) :631 - 639.
  • 8Okihiko Hirasa, Hisao Ichijo, Aiz, o Yamauchi. Oxygen transfer from silicone fiber membrane to water[J ]. Journal of Fermentation and Bioengineering, 1991,71 ( 30 ) :206 - 207.
  • 9Michael J Semmens,John S Gulliver, Anita Anderson. An analysis of bubble formation using microporous hollow fiber membranes[J ]. Water Environ Res, 1999,71:307 -315.
  • 10Vladisavljevic G T. Use of polysulfone hollow fibers for bubbleless membrane oxygenation/deoxygenation of water[J ]. Separation and Purification Technology, 1999, 17(1):1 - 10.