摘要
本文介绍了俄供TBB-1000型发电机转子绕组绝缘缺陷的定位及处理方法,并对缺陷的原因进行了详细的分析。该处理方法是在多年工作经验的基础上总结出来的,通过实践证明十分有效。对于改善俄供同类型发电机转子绕组的绝缘性能,提高其可靠性有良好的效果。
This paper presents an approach to location and solution on insulation defect for rotor winding of type TBB-1000 generator made by Russia, and also analyzes the reason that causes cause about the defect. The method on the basis of years working experiences is effective, which has been proven by practices. It is effective to improve the insulating property and reliability of rotor winding for the same type generator made by Russia.
出处
《大电机技术》
北大核心
2013年第4期17-20,共4页
Large Electric Machine and Hydraulic Turbine
关键词
发电机
转子
绝缘缺陷
绝缘波动
generator
rotor
insulation defect
insulation fluctuations