随着高校扩大招生和高校信息化技术应用的普及,计算机实训室的规模不断扩大,而传统的计算机实训室维护方式已经不能满足现时的需求,已无法能够及时发现实训室中电脑出现的故障,实验人员无法及时去处理,而且计算机维护效率低下。本文提出一种基于SNMP和CACTI集成监控系统的应用,通过对实训室流量进行监控与分析,达到及时发现计算机实训室中的电脑的故障,及时去处理,提高计算机实验管理人员的工作效率。
Along with the expansion enrollment and the popularization of information technology application in colleges and universities, the scale of the computer training lab increases rapidly, while traditional computer training labs' maintenance mode cannot meet the existing needs, cannot be unable to discover computer malfunction timely, and make the laboratory assistant unable to deal with in time and the computer maintenance is inefficient. The paper is reported an application that integrated SNMP and CACTI monitoring system, through the computer training labs traffic monitoring and analysis to discover the computers malfunction timely and in time to deal with, then to improve computer experiment management staff efficiency.